Fig. 2: Attachment point
5.3

Storage

44
Transportation and storage
NOTICE
Only use lifting equipment in a technically sound condition!
Only use lifting equipment in a technically sound condition for lifting, lowering and
transporting the pump. Ensure that the pump does not become jammed during lift-
ing and lowering. Do not exceed the max. permissible bearing capacity of the lifting
equipment!
CAUTION
Soaked packaging may tear!
The product may fall on the ground if unprotected and may be damaged. Lift wet
packaging carefully and replace it immediately!
Only remove the outer packaging at the place of utilisation to ensure that the pump is
not damaged during transport. Use tear-proof plastic sacks of sufficient size to pack-
age used pumps for transport in a leak-proof manner.
The following points must also be observed:
▪ Adhere to the applicable national safety regulations.
▪ Use legally specified and approved lifting gear.
▪ Select the lifting gear based on the existing conditions (weather, attachment point,
load, etc.).
▪ Only attach the lifting gear to the attachment point. Fix with a shackle.
▪ Use lifting equipment with sufficient bearing capacity.
▪ The stability of the lifting equipment must be ensured during operation.
▪ When using lifting equipment, a second person must be present to coordinate the pro-
cedure if required (e.g. if the operator's field of vision is blocked).
DANGER
Danger due to fluids hazardous to health!
If the pump is used in fluids hazardous to health, decontaminate the pump after dis-
mantling and before carrying out any other work! There is a risk of fatal injury! Ob-
serve the specifications in the work regulations! The operator must make sure that
the personnel have received and read the work regulations!
WARNING
Sharp edges on the impeller and suction port!
Sharp edges can form on the impeller and suction port. There is danger of limbs be-
ing severed! Protective gloves must be worn to protect from cuts.
CAUTION
Total damage due to moisture ingress
Moisture ingress in the power supply cable damages the power supply cable and the
pump! Never immerse the end of the power supply cable in a fluid and firmly seal it
during storage.
Newly supplied pumps can be stored for one year. Contact customer service to store
the pump for more than one year.
The following must be observed for storage: