Bühler technologies P1.3 Manuel D'utilisation Et D'installation page 44

Masquer les pouces Voir aussi pour P1.3:
Table des Matières

Publicité

Canadian Certificate Of Conformity No: FM16CA0191X
11.
The marking of the equipment shall include:
Class I Division 2, Groups A, B, C, D; T4...T3 Ta = 0°C to +50°C
12.
Description of Equipment:
The P1 sample gas pumps carry gases from various processes to analyzers. The gas circuit typically has
additional analysis components such as sample gas probe, filter, flow meter, cooler, etc. The sample gas
pump P1 consists of the main components, the pump head and motor. An eccentric converts the rotation of
the motor into an up and down motion using a connecting rod, thus producing the pump mechanism. Inside
the so-called pump body, above the bellows, which facilitates the pump motion, are inlet and outlet valves.
The user connects the gas circuits to the sample gas pump through screw-in connections.
The P1 sample gas pumps are available as 12Vdc, 24Vdc, 115Vac, 60Hz or 230Vac, 50Hz. The 115Vac
and 230Vac sample gas pumps have internal self resetting thermal protection built into the motor. The P1.3
sample gas pump is for hazardous locations and the P1.1 sample gas pump is for the US and Canada
general pupose non-hazardous locations.
Model Code Structure:
4230abc1def00. P1.3 Sample Gas Pump.
a = Motor voltage: 1, 2, 3 or 4.
b = Pump head position: 1 or 2.
c = Pump head material: 1, 2, 3 or 4.
d = Screw-in connections / pipe fitting: 0, 1, 2, 3, 5 or 6.
e = Mounting accessories: 0, 1 or 2.
f = Housing: 0 or 1
13.
Specific Conditions of Use:
1
4
1. The apparatus is to be installed in a tool-secured enclosure in compliance with the enclosure, mounting,
spacing and segregation requirements of the ultimate application.
2. To maintain a T4 to T3 temperature class care shall be taken to ensure the ambient temperature does
not exceed 50°C.
3. Temperature class are defined by the following table:
Type of Gas used in Pump
Non-Flammable
Non-Flammable
Flammable
THIS CERTIFICATE MAY ONLY BE REPRODUCED IN ITS ENTIRETY AND WITHOUT CHANGE
FM Approvals LLC. 1151 Boston-Providence Turnpike, Norwood, MA 02062 USA
T: +1 (1) 781 762 4300 F: +1 (1) 781 762 9375 E-mail:
F 348 (Mar 16)
SCHEDULE
Maximum Gas Temperature
50°C
70°C
50°C
information@fmapprovals.com www.fmapprovals.com
Temperature Class
at installation site
in gas path
T4
T3
T4
---
---
T3
Page 2 of 3

Publicité

Table des Matières
loading

Table des Matières