Mounting Of The Cps On The Pump; Cooling The Motor; Hydraulic Connection; Pressurised Tank - Expansion Vessel - Pentair CPS3-10 MULTINOX VE+ 4-120 Instructions De Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 49
EN

3.1 MOUNTING OF THE CPS ON THE PUMP

See figure at bottom of handbook (pag. 155).

3.2 COOLING THE MOTOR

Follow the precautions described below to ensure that the motor and electronics are cooled:
Install the pump in a well-aerated area
to guaranteed sufficient cooling to the
motor and electronics

3.3 HYDRAULIC CONNECTION

The system can be used with a direct connection to the aqueduct or suction from a first tank
(see chapter 8.2 – 8.3).
ATTENTION
For connection to the aqueduct, pay full attention to local standards in force.
ATTENTION
Check the sum of the intake pressure and the maximum pressure of the motor pump do not exceed the maximum values
allowed by the system.
TANK
Follow the indications described in the use and maintenance manual for the motor pump used.
It is possible to use a float to deactivate the system (to avoid the system drying up).

3.4 PRESSURISED TANK - EXPANSION VESSEL

ATTENTION
Check the maximum pressure of the tank can support the maximum pressure of the system.
It is necessary to install an expansion vessel on the outlet side of at least 8 liters to avoid the motor pump functioning continuously.
Check the preloading pressure of the tank before connecting to the system: this value must be 0.5/0.8 Bar less than working pressure
(lower SET-POINT).

3.5 MOTOR PUMP ELECTRICAL CONNECTION

DANGER
Ensure power is cut to all the connections.
DANGER
Always disconnect the electrical power cable before performing operations on the electrical or mechanical parts of the
motor pump.
DANGER
Having disconnected the power cable, wait for the LINE led to switch off (about 2 minutes) and until the condensers unload
before performing intervention on the CPS.
ATTENTION
Perform the electrical connections in compliance with local standards in force.
ATTENTION
It is the responsibility of the installer to ensure that the electrical power supply system has an effective earthing system in
compliance with standards in force.
26
Ambient temperatures should not be
above 50°C
Keep the cooling fins and ventilator
clean

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cps3-10 multinox ve+ 4-30Cps3-10 multinox ve+ 4-50Cps3-10 multinox ve+ 4-70Cps3-10 multinox ve+ 4-90Cps3-10 multinox ve+ 6-30Cps3-10 multinox ve+ 6-50 ... Afficher tout

Table des Matières