Manual Start/Stop; History - Saved; Signal Table - Pentair CPS3-10 MULTINOX VE+ 4-120 Instructions De Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 49

5.5 MANUAL START/STOP

It is possible to manually stop the pump by pressing the START/STOP button: in this situation the display alternatively shows the writing
STOP. During STOP status the module is not operative unless the anti-lock mode is activated (TAB parameters -
installation parameters 5.3.4). The word "abl" will be displayed if the condition is active.
START/STOP sequence of buttons,push the STOP button.
ATTENTION
Press the START/STOP button again to exit the STOP condition.
CHAPTER 6
SIGNALS, ALARM STATUS AND ERRORS

6.1 HISTORY - SAVED

Key sequence:
Press ESC for 5 seconds.
Press MODE to scroll the error log.
Press STOP to see the hour and the date of the event (when the clock has been set correctly).

6.2 SIGNAL TABLE

MESS. DISPLAY
DESCRIPTION
LOGO PENTAIR
System initiation signal.
System re-initiation
LOAD
signal.
RPC
Reset configuration.
REC
Saving parameter signal.
RST
Total reset signal.
RSE
Reset memory.
ESG
Memory reset carried out.
FAL
End of alarm (in memory).
ON
Complementary pump on.
STB
Complementary pump on standby.
The condition occurs when the system is first
started-up
or in a condition of reset and configuration of
the unit or after a prolonged power failure.
The condition occurs when a short power
failure takes place. It signals the loading of the
configuration
parameters and the setting of the clock.
ACTION
Wait for a change in status.
The board has been reset. It is caused by the manual
pressure of the reset button. The module will save all
the information recorded, with the exception of clock
setting (see chapter 7.2)
Request of reset of the eeprom memory (see chapter
7.2). The module returns to the factory settings.
Confirms that the eeprom memory has been reset (see
chapter 7.2).
Indicates the end of an alarm.
The complementary pump is on and regulating.
The complementary pump is on standby.