Data On The Power And Status Of The Radio Link; Operation In Multiple Configuration; Generalities - Tractel dynafor LLX2 Instructions D'emploi Et D'entretien

Masquer les pouces Voir aussi pour dynafor LLX2:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6.3.2.4 Radio link icon:

Data on the power and status of the radio link

30
31
GB
If several sensors are linked to the display unit, the weakest signal will be displayed.

7 OPERATION IN MULTIPLE CONFIGURATION

7.1 Generalities

Multiple configuration consists of linking up the four sensors to anything up to four display units (a master
display and 1 to 3 slave displays). The sensors can have different capacities.
(For more than four sensors the PC option is required. See chapter 8).
For some applications it is useful to display the measures coming from several sensors on just one
display unit.
Example: Lifting a load with a two- winch suspended load bar, each winch equipped with a sensor. The
grouping of the two strain measures on the same display unit enables the operator to view two
strains and their total and to check the correct distribution of the load between the two winches.
For other applications it is useful to have the display of the stress measurement from one sensor on
several display units.
Example: Two operators are manoeuvring a load. One guides the manoeuvre, the other monitors and
saves the stress levels. It should be noted that in an application with several display units, only
the "Master Unit", has control over the sensor, the other "Slave units", repeat the data coming
from the Master Unit.
Certain applications require several sensors on several display units.
Example: Complex manipulation of a load, like a hydro-electric power station turbine, carried out by
several participants, working on different levels.
Return to standard display
ESC
Return to standard display
Select an icon and enable the
available options
Select an icon and enable the
available options
Confirm selection
ESC
Return to standard display
Select an icon and enable the
available options
Select an icon and enable the
available options
24
Radio network parameter settings:
1
= 1 sensor detected.
1
= 1 display unit detected.
C : 8 = No. of selected radio
channel.
M = Display unit is Master.
(E = Slave unit).
= The sensor / display couple
is locked.
Radio network parameter settings:
1 NNN = sensor identification.
1 NNN = display unit identification.
C : 8 = No. of selected radio channel.
M = Display unit is Master. (E = Slave
unit).
= The sensor / display couple is
locked.
= Couple linked but not locked.
= Couple not linked.

Publicité

Table des Matières
loading