6.3.1.2.4. Dynamic effect filtering

Display
26bis
NOTE:

6.3.1.3. Languages

See section 6.2.4.6

6.3.2. Other icons on the standard screen

6.3.2.1 Sensor icon:
27
6.3.2.2. Display Unit icon:
28
6.3.2.3 Identification icon: ID - Display unit and sensor identification and data
29
Return to main display
ESC
Return to main display
Select a parameter, validate
with
arrows.
Select a parameter, validate
with
arrows.
In « Max » mode, the filter function is deactivated.
When the « Max » mode is exited, the filter function is automatically reactivated.
The measurements sent to the PC on the USB link are not filtered.

- Sensor settings and data

Return to standard display
ESC
Return to standard display
Select an icon and enable the
available options
Select an icon and enable the
available options

- Display unit settings and data

No action
ESC
Return to standard display
No action
No action
Return to standard display
ESC
Return to standard display
No action
No action
Action
, and modify using
, modify using
23
Comments
Filtering:
Display: used to stabilise the value
displayed by calculating the running
mean during the configured period.
Relay: used to time-delay triggering by
calculating the running mean during the
configured period. Only relays 1 to 4
are filtered; relay 5 is triggered
instantaneously.
Period : 0 to 5 s in steps of 0.25 s
Indicator, filter on display
Indicator, filter on thresholds
Indicator, filter on display and
thresholds
Sensor parameters display:
AD 22 = sensor address
Switch from standard to power saving
mode after 28ʼ if variation step > 15%
of the stress. Enabled
Switch to power saving mode in
standby.
Disabled X
TOTAL SHUTDOWN: Powers down the
sensor. To power up again you must
use the ON/OFF switch on the sensor.
Display unit parameter display:
AD = display unit address
This screen is displayed if the
sensor/display unit pair is locked.
Display identification of elements
in the network:
Sensor: Serial No., capacity,
hardware version, software
version, date of last
calibration or adjustment.
Disp. Unit: Serial No., hardware
version, software version.
GB