6.3.1.1.3 Safety threshold management

NOTE: Electrical use of the «Safety threshold management» function is only possible provided the LLX2
display unit is used as a component of the LLX2 Monitor equipped with 5 changeover relays (220 Vac 5 A).
Msmt in progress
Or, threshold
setpoint
Threshold1
Triggering
direction
Threshold not
activated
Threshold
in % of LLX2
capacity
22
Key for Threshold Management sub-menu
Scroll down line by line
Scroll up line by line
Trigger programmed threshold on upward
overshoot
Trigger programmed threshold on downward
overshoot
No programmed threshold trigger
Relay identification
R1
Alarm
Measurement
logo
units
No action
ESC
Return to standard display
Select an icon and activate
the available options
Select an icon and activate
the available options
Confirm selection
ESC
Return to previous display
Select an icon and activate
the available options
Select an icon and activate
the available options
Trigger on Raw
Radio reception
or NET
level
Safety threshold management:
This window is used to display:
- the value of the actual force.
- the programming state of the
5 relays.
- the trigger setpoints.
- the assignment of the sensors to
the various relays.
- the state of the audible alarms
Threshold management sub-menu:
Select the sub-menu.
See details and keys in table below.
Validate with "
The thresholds increment in steps
of 0.5% of the sensor capacity.
Adjustment range: 0 to 120% of
sensor capacity.
During the adjustment, the threshold
setpoint is displayed in the unit of
measurement used.
To modify threshold value
Programmed audible alarm
[1]
No. of sensor to which threshold is assigned
[T]
Threshold assigned to all sensors
Choice of trigger with respect to "gros" or "Net"
0
Reset number and overshoot time of programmed
threshold
21
Indicator :
Relay assigned to
sensor No.1 etc.
T = trigger on sum.
Duration H MM
SS of threshold
overshoot
Number (XX)
of threshold
overshoot
GB
Indicator :
Programmed
alarm
¸"

Publicité