CONNECTING TO THE MAINS POWER SUPPLY
-Before connecting the power supply, make sure the product's ratings match the mains ratings and that a
suitable residual current circuit breaker and overcurrent protection device have been installed upstream
from the electrical system. Install an omnipolar switch or circuit breaker on the mains power line that permits
full cut-off in overvoltage III category conditions.
- Make sure that upstream from the mains power supply there is a residual current circuit breaker that trips
at no more than 0.03A as well as any other equipment required by code.
- Make sure the earth system has been correctly installed: earth all the metal parts belonging to the entry
system (doors, gates, etc.) and all parts of the system featuring an earth terminal.
To connect auxiliary equipment (24V), use wires with a cross-sectional area of at least 0.5mm
-Wires must be secured with additional fastening near the terminals (for example, using cable clamps) in
order to keep live parts well separated from safety extra low voltage parts.