Press the OK key
Control unit software version
N. total manoeuvres (in tens)
N. manoeuvres since latest maintenance (in tens)
N. radio control devices memorised
param. 1
param. 2
end
param. . . .
logic
logic. 1
logic. 2
end
logic. . . .
radio
add. start
Add. 2ch
end
read
erase 64
COD RX
v
ITA
lingua
- +
FRA
- +
end
DEU
- +
ENG
- +
esp
PRG
default
end
autoset
end
l. s w adj
LIMIT SWITCH ADJUSTMENT
end
ACCESS TO MENUS
hidden button
hidden button
PRG.
+/-
2 2 F D
1 A 9 C
OK
OK
OK
OK
OK
OK
(Fig. F)
Scroll up
Scroll down
Confirm/Switch on display
See PARAMETERS MENU
See LOGIC MENU
release
desired button
release
desired button
01 t1
See RADIO MENU
0 1
OK
OK
Logic
Description
PED
partial opening input activated
STRe
START input activated
STOP
STOP input activated
PHOT
PHOT input activated
BAR
SAFETY EDGE input activated
CLOS
CLOSE input activated
OPEN
OPEN input activated
Suo
opening limit switch activated
Suc
closing limit switch activated
A P
reverse due to obstacle
autoset function is running
Set
WARNING! Obstacle detection function is not active
ER01
photocell test error
ER02
safety edge test error
ER10
mosfet test error
ER11
shunt test error
ER21
encoder test error
ER40
thermal cutout error
ER50
optional module communication error
35.40
Set torque threshold %
Maximum motor torque %
Cancel/return to main menu
o 01
o 01
ARGO-ARGO G -
13