Failure removal
Failures  
Engine does not start
Splitting knife is not moving
Hydraulic pump is whistling, split-
ting knife running jerkily
you need any spare parts or operating instructions?
We will quickly help you and without needles
bureaucracy at our web pages at www.guede.com
in the Servicing part. Please help us be able to help
you. In order to identify your device in case of claim
we need the serial No., product No. and year of pro-
duction. All this data can be found on the type label.
Tel.:
Fax:
E-Mail:
Causes
No power in the socket
Defective electric extension cable
Wrong connecting cable
Defective condenser switch
Adjust the two-hand control and
starting levers
Few hydraulic oil
Trigger is bent; hydraulic piston on
the valve is not fully seated
Wood has many knobs and the
splitting knife is getting stuck
Oil loss, bottom contamination
Few hydraulic oil
+49 (0) 79 04 / 700-360
+49 (0) 79 04 / 700-51999
support@ts.guede.com
Removal
Check the fuse
Pull the plug out, check it, replace it
5-wire connection at 2.5 mm2 cross
section
Have the machine checked by a
professional electrician
Defective control valve - to be
replaced in a service centre only
Hydraulic oil to be added
Check all screws on the trigger
Adjust the trigger so that the
hydraulic piston on the valve is fully
seated
Lubricate the splitting knife
Tighten the screws
hose
Hydraulic oil to be added
37
Replace the

Publicité