It is also necessary to clean the upper area of heat exchange, because the
soot that accumulates in them difficult the proper circulation of smoke. In
order to do this, the front of the coating must be removed first, caution must
EN
be taken TO NOT break the display cable before disconnecting it, and
then the following operations must be carried out:
-
Remove the existing piece of insulating material.
-
Remove the cover of register unscrewing the different screws.
-
Clean the ashes deposited in the register, descaling the soot that has
been deposited.
-
Replace the parts and check the tightness of the register and replace
the covers.
On this model it also has a rear register for the heat
exchange zone, which must also be cleaned by
following the steps below:
-
Remove the left side chamber of the existing
boiler on the back of the body.
-
Remove the register cover by loosening the
various screws.
-
Clean the ashes deposited in the register,
descaling the soot that has been deposited.
-
Replace the pieces and check the airtightness of
the register. Replace the covers.
Once the upper and rear areas have been cleaned, the smoke register located at the bottom of the boiler must be cleaned. To do this, remove the
decorative plate from the lower part and then carry out the following operations:
-
Remove the register cover by loosening the various screws.
-
Clean the ashes deposited in the register, descaling the soot that has been
deposited.
-
Also clean the blades and the extractor housing. Remove the extractor if necessary.
-
Replace the parts.
-
Check the tightness of the register.
11.8.
SEASONAL STOPPAGES
If the boiler is not going to be used for a long time it is advisable to leave the fuel tank
empty, as well as the auger in order to avoid the fuel compacting or gaining moisture
and expanding. It is necessary to clean the boiler and the smoke duct by removing the
ash and other residues, close all doors of the equipment. It is recommended to clean
the chimney at least once a year. Meanwhile, check the seals because if they are not in
good condition (they do not seal the door), they do not ensure the proper operation of
the boiler. For this reason, it would be necessary to change them. You can find this spare
part in the same Boreal distributor where you bought your boiler. If there is humidity in the
place where the boiler is installed, put absorbent salts inside the equipment. Protect the
internal parts with neutral vaseline in order to keep the appearance overtime time.
Your boiler has a system to prevent the blocking of the pump due to calcareous
sediments of the water of the installation. For this reason, it is necessary that, during the seasonal shutdowns, the boiler is connected to the
electric mains since it will automatically work for several seconds to move the impeller and prevent its locking.
48
Rear register assembled