SUBMENU 3.2.1 DAILY PROGRAM
This submenu allows the selection of three possible hours of lighting on and three possible hours of lighting off of your boiler. Independently of the week
day: Monday, Tuesday, Wednesday, Thursday, Friday, Saturday and Sunday. You can choose only one slot of running, two or even three slots each day.
In order for the programming to take effect, you must activate the "tick" on the right of the time zone by pressing the P5 key.
P1
Monday
Tuesday
Wednesday
P2
Thursday
P3
•
SUBMENU 3.2.2. WEEKLY PROGRAM
This submenu allows the selection of three possible hours of lighting on and three
possible hours of lighting off of your boiler for the 7 days of the week, from Monday
to Sunday, but it will do it the 7 days of the week. You can choose only one slot of
running, two or even three slots each day.
For the programming to take effect, you must activate the "tick" on the right side of
the time zone.
P1
Mon-Frid
Sat-Sun
P2
P3
Mon-Frid
P1
ON
12:00
P2
00:00
00:00
P3
9.6.4.
MENU 4. MANUAL AUGER LOAD
In the case the boiler during running on is out of combustible, alarm Er18 (low
combustible).
To deactivate the alarm, press button P2 for 3 seconds and the boiler will go into
the stopped state.
To initiate a new start, it is necessary refill the combustible hopper before we switch
on again the boiler P2, other way your boiler will not show any alarm, but it will not
allow you to switch on.
However, when the boiler is stopped and cold and the door closed it is possible to
do a pre-load of pellets during a maximum time of 600 seconds to load the auger
To start this load go to menu "manual load" and after pressing key ON and confirm
with key P3, the auger will automatically start moving; you will see how the smoke
extractor will start during the load as a security mode. To stop this load press the line
OFF and confirm with key P3 .
Do not forget before switching on the boiler proceed to totally empty the pellet burner to avoid a dangerous situation.
P4
P5
P6
P4
SUBMENU 3.2.3. WEEKEND PROGRAM
•
P5
This submenu allows the selection of three possible hours of lighting on and
three possible hours of lighting off of your boiler for the days Monday, Tuesday,
Wednesday, Thursday and Friday; and other three different possible hours of
P6
lighting on and off for Saturdays and Sundays. You can choose only one slot of
running, two or even three slots each day.
For the programming to take effect, you must activate the "tick" on the right side of
the time zone.
P4
OFF
21:00
P5
00:00
00:00
P6
Monday
P1
ON
OFF
07:00
10:30
P2
00:00
00:00
00:00
00:00
P3
Mon-Sun
P1
ON
08:00
P2
00:00
00:00
P3
Sat-Sun
P1
ON
OFF
12:00
21:00
P2
00:00
00:00
00:00
00:00
P3
P1
Manual Auger Load
P2
ON
P3
EN
P4
P5
P6
P4
OFF
22:00
P5
00:00
00:00
P6
P4
P5
P6
P4
P5
P6
43