BOILER RUNNING

Once smokes temperature reach the set up the boiler considers it is working, then will switch to "stabilization" during a few minutes before ending the
lighting process.
EN
P1
P2
P3
Once the stabilization process is finalized the boiler is in mode "Run mode" represented by the normal working mode. The display will show the time,
date, working power, water temperature, thermostat temperature and winter/summer mode.
9.5.3.

WATER TEMPERATURE ADJUSTEMENT

This function is only available inside the user menu. Check the chapter 9.6.2.1.
9.5.4.

WORKING POWER ADJUSTEMENT

This function is only available inside the user menu. Check the chapter 9.6.2.2.
9.5.5.

ROOM TEMPERATURE REACHES THE REQUESTED VALUE BU THE USER

When room temperature reaches the requested value by the user, the boiler receives the order through an external thermostat connected to the boiler and
automatically start the switch of process, and will switch on automatically when room temperature in under the consigned temperature. This depends on
the thermostat hysteresis installed in your house.
9.5.6.

WATER THERMOSTAT REACHES THE REQUESTED VALUE BU THE USER

When the water temperature of the boiler reaches the requested value by the user, the boiler start mode "stand by", i.e. starts modulation lowing the
power to adequate to the selected temperature of the water and keep on working. In this case it is possible that your house do not reach the temperature
requested from the external thermostat because the water temperature value that you have fixed is low for your comfort temperature. We recommend
putting an enough temperature value (70-75º) to allow the boiler keep on working and reach your house comfort temperature.
9.5.7.

CLEANING THE BURNER

During the standard working of the boiler automatic cleaning processes are
appearing periodically. The cleaning remains during a few seconds and it consists
on cleaning the rest of pellet in the burner, blowing (increasing the exhaust fan
speed) and therefore help the proper function of the boiler. During this process the
display will show the following message:
9.5.8.

BOILER SWITCH OFF

To switch off the boiler we have to push the key P2 during three seconds. Then the
boiler start the end cleaning process where the auger stop and the smoke extractor
works at maximum power. This process will not finish until the boiler has reached the
proper cooled temperature.
Meanwhile you will see these messages in the display:
P1
P2
P3
40
Fri 18:35

RUN MODE

Pl Man
21º
65º
Pellet 1
Fri 18:35
EXTINGUISH
Pl Man
21º
65º
Pellet 1
P4
P1
P5
P2
P6
P3
P1
P2
P3
P4
P1
P5
P2
P6
P3
Fri 18:35
NORMAL
Pl Man
21º
65º
Pellet 1
Fri 18:35
CLEANING ON
Pl Man
21º
65º
Pellet 1
Fri 18:35
OFF
Pl Man
21º
65º
Pellet 1
P4
P5
P6
P4
P5
P6
P4
P5
P6