SWITCH ON AGAIN THE BOILER

Once the boiler is switch off it will not be able to switch it on again until some
security time has elapsed and the boiler is cool enough. If you try switch on the
display will show the message "Recover. Ign."
Once security time has passed the boiler will switch on again starting a new lighting
cycle.
Fri 18:35
P1
OFF
Pl Man
P2
Pellet 1
P3
9.5.11.

BOILER IN ALARM

When the boiler is under alarm mode, on the display you will see the following
screen with the corresponding error code while the boiler starts the cooling process.
To unlock the boiler, press the P2 key for 3 seconds and the boiler will start the
unlocking process, and then you will be able again to proceed with the ignition
of the boiler. Note: There are alarms that require the intervention of the Technical
Assistance Service to be unblocked.
9.6.

END USER MENU 1

To access user menu1 it is necessary push only once the key P2 in the display.
The following table briefly describes the structure of the boiler user menu 1. The options available to the user are specified.
In order to select the different menus, simply press keys P4 (up) or P6 (down) and confirm the submenu you want to access with key P3.
In order to exit from the submenu or to move up a menu level, press key P1.
9.6.1.

MENU 1. POWER

This menu modifies the combustion power.
9.6.1.1.

COMBUSTION

You can change the boiler power according to the available values: power 1, 2, 3,
4, 5 or A (A = automatic combustion). The value entered must be confirmed with the
P3 key before exiting the menu.
P4
21º
65º
P5
P6
Menu
Power
Combustion
Thermostats
Boiler
DHW
Chrono
Modality
Program
Manual load Endless
screw Axle
P1
P2
P3
9.5.10.

BOILER STOPPED

In the next picture you will see the message the display will show when the boiler
is stopped.
P1
P2
P3
Submenu 1
Submenu 2
1, 2,3, 4, 5 and A
Value between 40 and 80ºC
Value between 40 and 55ºC
Daily, Weekly, Week-end
On/Off
P1
P2
P3
Fri 18:35
RECOVER ING.
Pl Man
21º
65º
Pellet 1
Er 01
Fri 18:35
IGNITION
Pl Man
21º
65º
Pellet 1
Combustion
Pot: 5
P4
EN
P5
P6
P4
P5
P6
P4
P5
P6
41