Before cleaning the device, disconnect it
from the power supply by removing the plug
or batteries.
NOTE!
Use only the recommended batteries. Always
replace weak or empty batteries with a new,
complete set of batteries at full capacity. Do
not use batteries from different brands or with
different capacities. The batteries should be
removed from the unit if it has not been used
for a long time.
Never recharge normal, non-rechargeable
batteries. This could lead to explosion during
the charging process.
Do not disassemble the device. In the event
of a defect, please contact the Service Centre
in your country (see the warranty card).

Operating instructions

Parts overview (Fig. 1+2):
B
5x WF Eypiece
C
16x WF Eyepiece
D
Barlow lens
E
MicrOcular (PC-Ocular)
F
Eyepiece holder
G
Microscope head
H
Objective-revolver
I
Microscope stage
J
Focus wheel
1)
LED lighting (transmitted light)
1!
Illumination ON/OFF
1@
Microscope base
1#
Photomizer software
1$
Battery compartement
1%
5 Slides, 10 Covering glasses and
5 preparations in a plastic box
1*
Dimmer
1(
Colour filter disc
2)
LED lighting (direct light)
2!
Direct light / transmitted light switch
2@
Microscope tools:
a) Pipette; b) Tweezers
2#
Prawn breeding plant
2$
MicroCut
2%
Specimens: a) yeast; b) Gum media
(specimen inclusion medium); c) sea salt;
d) Prawn eggs
2^
Locking screw
1. General/Location
First you must make sure that your microscope
is on a stable and solid surface.
2. Electric LED lighting with dimmer
Check before use whether the light switch
(Fig. 1,21) is set to "off".
The microscope has two lighting units. Lighting
can be of three types. Set the switch (Fig 1, 21)
to „II" to light the specimen from above (reflected
light) or „I" to light it from below (direct light). Use
setting „III" to have the specimen simultaneously
subjected to direct and transmitted light. The
transmitted light unit (Fig 1, 10) is used for
transparent specimens (those on glass slides).
To view solid non-transparent specimens use
the direct light unit (Fig 1, 20). Use of both forms
of lighting simultaneously is only recommended
for semi-transparent specimens. This operating
mode is not recommended for direct light
specimens on slides as it may cause reflection
on the slide.
The batteries supplied should be inserted into
the battery compartment located in the base
plate before use. (Fig. 1. 14)
Remove the battery compartment cover by
pressing lightly on the cover clip. Insert the
batteries into the holder.