4.8 Thermostat - external chronothermostat
The unit controls the room temperature by means of its own digital thermostat whose
function is to detect the temperature through a probe and lower the heat output when
the set temperature is reached.
To use an external thermostat, contact an authorised technician and proceed as
follows:
- turn off the power by means of the main switch on the back and detach the power
cable;
- remove the side panel to access the electronic controller;
- referring to the wiring diagram, connect the two wires of thermostat to the respective
board TERM terminals;
- refit everything and check correct operation.
The setting procedure is as follows:
- external thermostat:
- external chronothermostat: SET the temperature to 7°C and disable the chrono
All the menu functions do not change for each of the settings and signalling of the
connection occurs with lighting up of the segment LED on the status bar of the
display.
4.9 Hot air fans
The ELLISSE DUCTABLE stove has three fans, with independent operation, for heat exchange with the combustion
chamber:
- middle fan – duct B : draws fresh air from below, the flow is conveyed to the rear wall and the upper exchanger of
the heating chamber and exits through the front panel of the stove into the room;
- left side fan – duct A : draws fresh air from below, the flow is conveyed to the left side wall of the heating
chamber then, by means of a valve, to the top front panel of the stove or to the rear left connection of the ducting
system;
- right side fan – duct C : draws fresh air from below, the flow is conveyed to the right side wall of the heating
chamber then, by means of a valve, to the top front panel of the stove or to the rear right connection of the ducting
system;
4.9.1 4.9.1 Hot air flow setting
The stove can direct the hot air flows generated by the right fan (duct C) and left fan (duct A) to the top front panel
or the back of the stove to suitable ducting system connections by means of the valves.
The manual control levers located inside the pellet hopper allow the hot air flow to be diverted entirely and also the
creation of a modulation between the air flow in the room and that conveyed in the ducting, using the middle
references of the control travel as illustrated below.
SET the temperature to 7°C;
functions from the menu 03-01.