4.6.7 Menu 07 – initial loading
The setting of INITIAL LOADING allows pellet preloading for a time equal to 90 sec. with the stove off or cold. It is
started with the button P1 and stopped with the button P4.
4.6.8 Menu 08 – stove status
With this selection it is possible to display the instantaneous stove status giving the operating status of the various
devices connected to it; various pages placed in succession are available for monitoring.
4.6.9 Menu 09 – settings by technician
This selection is reserved for the authorised technician of the COLA service centre.
Modification of the technical parameters of menu 09 must be done by authorised and competent
personnel; any changes made at random can cause serious damage for which COLA declines any
liability.

4.7 Remote control

The remote control works with the settings made in the control panel and allows stove lighting-shutdown, and
adjustment of the required output and temperature.
Since this device transmits through an infrared diode, it must be pointed at the receiver unit in the control panel.
The remote control allows the following operations:
4.7.1 4.7.1 Replacing the battery
The remote control comes without the battery; it works
with a battery placed in the lower part of the device.
To fit or replace the battery, proceed as follows:
- Open the cover on the back of the remote control;
- Replace the 12V battery model p23ga, respecting the polarity;
- Close the remote control;
- Check that it works properly;
- Keep the remote control away from heat sources and water.
- The battery of the remote control must be replaced and disposed of in a safe
way, respecting the local regulations.
Button 'P1'
L : LED lit up by pressing any button
Button P1+P6 : Stove lighting-shutdown
Button P1: Increase room temperature
Button P6: Increase output level
Button P5: Decrease output level
Button P2: Decrease room temperature
Output
Button 'P4'