4.5 Shutting down
To shut down the stove, just press the button 'P4' for about 2 seconds.
The auger is stopped immediately and the fume extractor is brought to high speed, with the message 'CLEANING
FIRE POT ' displayed; both fume extraction and air ventilation motors remain on until the stove temperature has
lowered sufficiently.
At the end of the operation the message 'OFF' appears in the dialogue box.
During the shutdown stage the stove cannot be restarted until the fume temperature has fallen below a set value for
a fixed time, with the message 'WAITING COOL' appearing in the dialogue box.
4.6 Menu
Press the button 'P3' (SET) to access the menu; this is divided into various items and levels for accessing the
settings of the electronic controller.
The following table summarises the menu structure with the selections available to the user.
Level 1
01 – Adjust fans
02 – Set clock
Level 1
03 – Set chrono
Clock
Dialogue box
Level 2
01 - day
02 - hours
03 - minutes
04 - day
05 - month
06 - year
Level 2
01 – enable chrono
02 – day program
03 – week program
Room temperature
Output
Button 'P4'
Level 3
Level 3
01 – enable chrono
01 – day chrono
02 – start 1 day
03 – stop 1 day
04 – start 2 day
05 – stop 2 day
01 – week chrono
02 – start 1 day
54
Level 4
Value
Select value
Day
Hours
Minutes
Day
Month
Year
Level 4
Value
on / off
on / off
time
time
time
time
on / off
time
ELLISSE CAN 2011