ENGLISH
OPERATING MANUAL FOR
RECESSED GROUND LUMINAIRE
1000384
Read this short manual carefully and keep it accessible for further
reference!
SAFETY MESSAGES
Disregard of the safety messages may lead to danger of life, burning or
fire!
Installation, mounting or works on the electrical connection may only be
carried out by an approved electrician.
Type Y attachement: If the external flexible cable or cord of this luminaire is
damaged, it shall be exclusively replaced by the manufacturer or a
qualified electrician.
Do not look directly into the light source.
The product may not be modified or converted.
Do not hang or fasten anything on the product, especially no decoration.
Do not cover the product - provide free air circulation.
The luminaire may only be operated with a complete and intact protection
glass.
The cable of the luminaire may not be placed underground.
In case of a malfunction you may NOT touch the product or operate it
further. Disconnect the product from the power supply by an external
switch or by the fuse.
A malfunction exists when:
visible damages appear.
the product does not work properly (e.g. flickering).
smoke, steam or crackling sounds appear.
smell of burning is recognisable.
an overheating is recognisable (e.g. by discolouration of adjacent
surfaces).
Operate the product only after maintenance and examination by an
approved electrician!
This product is not intended to be used by children. Ensure that children do
not suffer any harm e.g. by burns from hot surfaces or by electrical shock.
Additional safety messages are indicated by this symbol:
USE AS DIRECTED
This product serves exclusively lighting purposes and may:
only be used with a voltage of 220-240V ~50/60Hz.
only be installed according to safety class I (one).
only be operated when firmly mounted on a stable, even and tilt-fixed
surface.
only be operated on normally or not flammable surfaces.
not be exposed to strong mechanical loads or to strong contamination.
MAINTENANCE AND CARE
Light source
The light source of this luminaire may only be replaced by the manufacturer,
an authorized service technician or a comparable qualified person.
Care
The following enviromental influences may have unwanted effects on the
surface of the product:
acid rain and sour soil, high salt content in the air
cleaning agents, fertilizer especially in flowerbeds
thawing salt, other chemical substances (e.g. herbicides)
Protect the product by adequate means to avoid unwanted changes of the
surface.
Disconnect the product from the power supply and let it cool down, before
you clean the product.
Clean the product on a regular basis using a slightly moistened, soft and fluff-
free cloth. Please also note additional supplied notes on maintanance and
care.
Remove leaves and dirt regularly.
STORAGE AND DISPOSAL
Storage
The product must be stored in a dry and clean environment. Do not strain
the product mechanically during storage.
After a damp or soiling storage the product may only be installed after
checking its condition by an approved electrician.
Disposal (European Union)
Do not dispose the product with the regular household waste! Products
marked with this sign must be disposed according to the directive (WEEE,
2012/19) on electrical and electronic devices at local collection points for such
devices!
INSTALLATION
(only by an approved electrician)
Switch off the mains or respectively the connection lead before doing any
works!
Use only parts, which are supplied with the product or are described as
accessories!
Inspect the product for loose parts inside the housing. When there are loose
.
parts inside the housing and these are not explicitly described the product may
not be installed or operated.
Use the supplied fastening material only when it is suited for the installation
background. If this is not the case use only fastening material suiting the
installation background.
Unpacking
Carefully take the product out of the packaging removing any transport
safeguards.
Before disposal of the packaging material make sure that all components of
the product are removed.
Installation place
The product is solely suited for recessed floor installation.
The cable of the luminaire may not be placed underground.
Note that maintaining the IP class 65 / IP class 67 requires an
appropriate connection corresponding with this IP class.
IP65: Protection against dust (dust-tight) - Protection against jetted water from
all directions.
IP67: Protection against dust (dust-tight) - Protection against the
penetration of water when temporarily submerged.
Prepare the power supply lead according to valid rules for outdoor
installations.
Do not seal the product yourself, using additional silicon or another
sealant.
Before installation
Do not remove the grease on the crews and the screw holes! The grease
inhibits anodic corrosion (electrolysis). Renew the grease on the screw
connections after each time the fixture has been opened.
Carry out the installation when the weather is dry.
Installation steps (read completely before installation)
Prepare the recess if not done yet. When installing the lighting unit
outdoors provide a gravel bed, 20 cm thick, beneath the installation pot.
This serves as protection from corrosion.
Install the luminaire as shown in the figure.
Electrical Connection
Use a suitable outdoor connection box (e.g. art.-no. 228730), to
connect the luminaire.
The product must be able to be separated by an all pole separation
from the current supply.
For electric connection attach the black or brown wire (live conductor)
of the connection lead with the clamp L and the blue wire (neutral
conductor) of the connection lead with the clamp N. The green-yellow
wire (protective conductor) of the connection lead has to be tightly
connected with the earth clamp
of the product.
All connections must be properly protected and sealed against
penetration of water and dirt!
Check if the product functions properly and is securely fixed!
art.-no. 1000384 © 14.07.2017 SLV GmbH,
Daimlerstr. 21-23, 52531 Übach-Palenberg, Germany,
Tel. +49 (0)2451 4833-0
Technical Details are subject to change.