Following thermostats are approved to be used:
T2FloorTemp and TA thermostat with floor sensor limited to 30°C
T2DigiTemp and TC thermostat with floor sensor limited to 35°C
It is recommended to install the sensor cable in a conduit
(included), so that it is possible to replace a defective sensor easily. The
conduit must be sealed properly by means of the cap (included). The
sensor itself should be located close to the surface immediately under
floor tiles or other floor covering and should be positioned centrally
between two heating cables. Avoid mechanical damage to the heating
cable ! Strive for a positioning of the floor sensor as close as possible to
the top floor surface for best temperature control. When installing two
heating mats, the sensor should be positioned between these two mats.
In case of damage a splice kit can be used. Please observe all applicable
regulations concerning installation.
Technical data
Nominal voltage
Power output
Circuit breaker
Min. bending radius
Min. cable spacing
Max. exposure temp.
Min. installation temp.
Conductor cross-section of
cold lead cable
Length of cold lead cable
Approvals
T2QuickNet-N
AC 230 V
up to 90 W/m²
See Fig. C and D
30 mm
90 mm
+90°C
+5°C
3 x 1,0 mm²
2,5 m
VDE
SEMKO
T2QuickNet-P
AC 230 V
up to 160 W/m²
30 mm
70 mm
+90°C
+5°C
3 x 1,0 mm²
5,0 m
VDE
SEMKO
7