Connecting the Faucet
CAUTION: Water supply to the inlet of the ROM IV RO System
should have a separate shut-off valve. If it does
not, a separate shut-off should be installed.
1 . Locate the 3/8" blue tubing from the faucet . See Figure
5 . The tubing must not have sharp bends or kinks that
would restrict water flow . Cut length as needed . Place a
mark 3/4" (1 .9 cm) from the end of the tubing .
IMPORTANT: A length of this 3/8" blue tubing will be
used to connect the storage tank to the manifold . When
cutting this tube, plan for the new piece to be used for
the tank .
Moisten the end of the tubing with water and insert
into the water outlet quick-connect fitting on the head
assembly . Push in until the mark is flush with the
quick-connect fitting .
2 . Gently pull back on the tubing to ensure it is connected
properly . If the tubing comes out of fitting, cut a small
section off of the tubing and reconnect .
NOTE: Tubing may be quickly and easily removed from the
fitting if necessary. First, turn off the water supply to
the filter. Open faucet, then press in the collet around
the fitting while pulling the tubing with your other hand.
To Cold Water Faucet
Water
Supply
Adapter
Cold Water Supply
Carbon Filtered
Only Water Out -
Remove Plug
Untreated
Water In
ROM IV REVERSE OSMOSIS SYSTEM INSTALLATION AND OPERATION GUIDE
Red 3/8"
Blue 3/8"
Figure 5