Supervision Mode: Select which receivers should be supervised
Protocol: Application protocol used to format the data field of the transporting protocol
SIAIP DC09 (SIA Level 3, KPROT for compatibility with the Vigilo receiver).
Application ID: ID of Application protocol of control panel, used with the current receiver.
Transport ID: ID SIAIP DC09 of control panel used with the current receiver, maximum 12 hexadecimal
digits. The device allows you to send signals to a main receiver, and possibly, to an optional second-
ary one for backup. The following data must be programmed for both receivers
Ethernet IP: IP address of the receiver to be used when the message is sent via Ethernet
Ethernet port: Remote port on which is listening the receiver when the message is sent via Ethernet
GPRS IP: IP address of the receiver to be used when the message is sent via GPRS
GPRS port: Remote port on which is listening the receiver when the message is sent via GPRS
Receiver ID: SIAIP DC09 ID of receiver, maximum of 6 hexadecimal digits.
EN
3. Network Options
In this section, the IP connection parameters are configurable. They are the classic parameters of a
network device and their description is omitted in this manual.
By default, the card is set with a static IP address 192.168.2.96, netmask 255.255.255.0, default gate-
way 192.168.2.1 and it keeps it until those settings are changed (or it is received an address from the
DHCP server).
4. Contact ID Options
In this section the options relating to the receivers Contact ID are configurable. They can be config-
ured up to 2 receivers.
Enabled: Select this option to enable sending of communications.
Telephone Number: phone Receiver number Remote Contact ID.
Customer Code: 4-figures customer code.
SCENARIOS
In the control panel can be configured up to 6 different scenarios that can then be activated by
keypad or remote control. A scenario is a sequence of actions (switching outputs and / or call
execution and / or arming) executed with a single command by the User. The parameters that can
be changed are:
Description: Scenario Description
Outputs: Each scenario can control up to 4 outputs in "off", "on" and "Toggle", depending on
whether it is required to turn off, turn on or toggle current status
output when running the scenario.
Arming Mode: Select the arming mode that you want to possibly run at the activation of the scenario
Enable communications: If this option is selected, the scenario will send the calls and / or SMS to all
directory numbers enabled. Obviously every scenario can also be programmed to perform only a
part of the programmable actions. You can activate one of six scenarios by long pressing the keys '4',
'9' on the keypad in the panel or on the wireless keypad. or by remote control, by pressing the keys
long (
) and (
) or in panic mode, pressing any button.

VOICE MESSAGES

In this section you can customize the voice messages and generate new ones through the text-to-
speech (TTS) functionality. To take advantage of the TTS function, it is necessary to make a remote
configuration via the portal or APP, after having previously purchased a valid license. The control
panel still has a set of pre-recorded messages.
REAL TIME
This section is for the installer to check real-time system status and verify the proper operation.

EVENT LOG

In this section the user can check the complete event list, with the details of date, hour and registered
user event generator.