G- TECHNICAL ASSISTANCE

G1- Troubleshooting
Problem
The gate doesn't move when pressing the
button of the transmitter
The transmitting distance is too short
The Flashing light does not work
The leaves suddenly stop during moving
The leaves does not move or only move
toward one direction
The master gate closes to the end first and the
slave gate stops, which the opening or closing
sequence is not being operated properly
The gear motors does not run and the relay is
noisy when operating the gate opening and
closing
No remote control connection

H- WARRANTY

The invoice will be required as proof of purchase date.
Are never covered by our warranty:
• Damage resulting from the consequences of a bad installation (bad wiring, reverse polarity ...).
• Damage resulting from improper use of the device (use in contradiction with the manual) or
its modification.
300 Kg
• Damage resulting from the consequences of the use of components not from SCS SENTINEL.
• Damage due to lack of maintenance, physical shock.
• Damage due to weather: hail, lightning, strong wind etc..
• Returns made without a copy of the invoice or receipt.
30
EN
1. Check if LED1 is "ON" once press the transmitter.
2. Check if the voltage of the batteries is above 22V.
3. Check if LED2 is "ON" and blinks accordingly.
4. Make sure all the wiring connections are firmly connected
to the terminals on the PCB.
5. Make sure the fuse is workable. on the panel and power
socket.
Make sure the connecting terminals of the Antenna is firm.
Check the battery on the trasmitter.
Check if the wiring connection of the flashing light is correct.
1. Check if the gate can be moved freely and no obstacles in
between.
2. Make sure the wiring connection of the gear motors is firm.
3. Make sure the fuse is workable.
4. Make sure there is no obstacle in the photocells beam.
5. Cut off the power of the engine. Release the motor and
make sure the gate can move freely.
1. Check if the gate can be moved freely and no obstacles in
between.
2. Make sure the wiring connection of the gear motors is firm.
3. Make sure the fuse is workable.
4. Make sure the safety beam are operating properly if
installed.
5. Cut off the power of the engine. Release the motor and
make sure the gate can move freely.
6. Increase the power with the switch 2 & 3.
Check the condition fuse.
1. Check LED1 is blinking when pressing the remote control key.
2. Check RF1 receiver is ok.
Solutions