E
EMERGENCY RELEASE
In case of power failure, push the lid of release chamber and move forward. Insert the key and
turn clockwise to unlock, then turn around the knob to release. To restore the automation, simply
reverse the above procedures.
Step1. Push the lid of release chamber and move forward
Step2. Insert the key and turn clockwise to the unlock position
Step3. then turn clockwise the knob to release the motor.
Make sure the White bar on the knob is on the position
opposite to the triangle indication.
To restore the automation, simply reverse the above procedure.
Step 1
1.3 TECHNICAL FEATURES :
Motor
Type
Max Absorbed Power
Peak Thrust
Nominal Thrust
Stroke Length
Power Supply
Nominal Input Power
Maximum Operating Current
Maximum Gate Weight
Maximum Gate Length
Duty Cycle
Operating Temperature
Dimension
Weight
Step 2
24Vdc motor with mechanical release
Worm gear
144W
3000N
3000N
300mm
24Vdc
2A
5.5A for maximum 10 seconds.
300 kg per leaf
3 meters
20%
-20℃~+50℃
837mm x 123mm x 124mm
6.6kg
Step 3
4