LED1
D- SETTING/USING
LED2
LED3
D1- Single/double gate setting (dip switch 1)
LED4
OFF
ON
SW1:Set
1. D/S set
2. Over_C1
3. Over_C2
4. Auto
5. Ph
NONE
ELECTRONIC CARD
D2- Power setting (dip switch 2 et 3)
DIP SWITCH OVER C1
DIP switch 2 OFF
DIP switch 2 OFF
DIP switch 2 ON
DIP switch 2 ON
RX
D3- Gate auto-close adjustment (dip switch 4)
DIP SWITCH 4
« ON » : Active automatic closing in 30 seconds. Simultaneously pressing the two remotes top keys
photocellules
closed gate) will turn OFF the automatic mode (the blinker will flash 3 times as confirmation).
Repeat the operation to turn ON the automatic mode (the blinker will flash 3 times as confirmation).
Note : in case of automatic closing, photocells are required.
« OFF » : Automatic closing OFF (caution it will still be possible to turn ON with the remote)
D4- Photocell adjustment (dip switch 5)
DIP SWITCH 5 :
ON : Photocells ON. When the photocells detect an obstacle while the gate is closing, the gate stops and opens
during 2 seconds.
If the gate auto-close is adjusted, and the photocells detect an obstacle when the gate is totally opened, then
the closing time will be reseted.
OFF : Photocells OFF. No detection by the photocells.
D5- Dephasing of the leaves (dip switch 6)
DIP SWITCH 6 :
ON : Dephasing in closing / opening of 8 seconds.
OFF : Dephasing in closing / opening of 3 seconds.
D6- Decelaration speed
The speed is 70% output of the full speed.
26
EN
1
2
3
4
5
6
TX
sélecteur
à clé
Switch settings: «on» right position, «off» left position.
DIP SWITCH 1 D/S set :
ON = double gate operation
OFF = single gate operation (connection on 5 and 6)
7
8
9
10
DIP SWITCH OVER C2
Dip switch 3 OFF
Dip switch 3 ON
Dip switch 3 OFF
Dip switch 3 ON
bouton
feu
poussoir
clignotant
24V 10W
250V
11 12 13 14
CURRENT (AMP)
4A
3A
2,5A
2A
serrure
M1
12/24V
M2
(opened or