22. Before proceeding with reloading, the system must undergo the pressure
test with OFN and the tightness test at the end of reloading, but before
commissioning.
It is necessary to carry out an additional tightness test before leaving the
site.
23. Collected refrigerant must be returned to the fluid supplier in the appropriate
collection cylinder, compiling the corresponding Transfer Note of Scraps.
DO NOT mix the refrigerants in the collection units and, in particular, in the
cylinders.
24. If the compressors or their oils must be removed, make sure they have been
emptied at an acceptable level to be sure that the flammable refrigerant
does not remain in the lubricant.
This process must be carried out before the compressor returns to the
suppliers.
Only use electric heating on the compressor body to speed up this process.
25. Once installation is complete, check that there's no loss of refrigerant (the
refrigerating liquid produces toxic gas if exposed to a flame).

0.5 - PROPER USE

• The air-conditioner should be used for the exclusive purpose of producing
hot or cool air (on demand) for the sole purpose of obtaining a comfortable
temperature in the room.
• An improper use of the devices (external and internal) with possible damages
caused to people, things or animals relieves OLIMPIA SPLENDID from any
liability.

0.6 - HAzARDOUS zONES

• The climate controllers must not be installed in environments with the presence
of inflammable gases, explosive gases, in very humid environments (laundries,
greenhouses, etc.), or in places with other machines that generate a strong
heat source, in proximity of a sources of salt water or sulphurous water.
• DO NOT use gas, gasoline or other inflammable liquids near to the climate
controller.
• The climate controller does not have a fan for the introduction of fresh outdoor
air into the room; ventilate by opening doors and windows.
• Always install circuit breaker and a dedicated power circuit.