The RF5132 v5.1 features two LEDs to help and with the installation of devices troubleshoot the operation of the unit.
In normal operation the LEDs will indicate if the signal received is from an enrolled device or not.
• The green LED will flash when receiving a signal from an enrolled device.
• The red LED will flash when receiving a signal from a non-enrolled device.
Alternatively, when the panel is in placement test mode, the green LED will only flash for the specific serial number
entered. All other signals (including signals from valid enrolled devices) will flash red.
1. When I enter the 2-digit zone number for adding a wireless device, the keypad gives me
a long beep.
ESNs can be entered only when a RF5132 wireless receiver is connected to the Keybus. See section 2 for instructions on
setting up and wiring the RF5132 module.
2. I have entered the ESN for the device but when I violate the device, the zone does not
show open on the keypad.
Check the following:
• Ensure the ESN has been entered correctly.
• Ensure that the zone is enabled for the partition (if partition programming is used).
• Ensure that the wireless zone is not assigned to a zone used by PC5108 modules, an on-board zone, or a keypad
zone.
• Ensure that the zone is programmed for something other than "Null Operation", and that the wireless zone attribute
is turned on.
3. When I try a module placement test I get no result or 'bad' results.
Check the following (see sections 5.1 and 5.2 for more information on testing devices):
• Verify that you are testing the correct zone.
• Verify that the correct ESN was entered when the device was enrolled.
• Verify that the device is in range of the RF5132. Try testing the device in the same room as the receiver.
• Confirm that the RF5132 is properly connected to the Keybus (see section 2 for RF5132 set up and wiring
instructions).
• Check that you are testing the zone correctly (see sections 5.1 and 5.2 for testing instructions).
• Check that the batteries are working and installed correctly.
• Look for large metal objects that may be preventing the signal from reaching the RF5132.
The device must be located where consistent 'good' results are obtained. If several devices show 'bad' results, move the
receiver. See section 2.2 for tips on choosing a mounting location for the RF5132.
4. The LED on the motion detector does not turn on when I walk in front of the unit.
The LED is for walk test purposes only. See your Wireless PIR Instruction Sheet for walk test instructions.
Section 7: Troubleshooting
16