DSC PowerSeries RF5132-433 Manuel D'installation page 23

Masquer les pouces Voir aussi pour PowerSeries RF5132-433:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

[90] Other Options
Default
NA
EU
Off
Off
On
Off
On
Off
On
Off
Off
Off
On
Off
Off
Off
RF Jamming Detection
[93] RF Jam Detect Zone (Default = 00)
l____l____l Select an unused zone that will be violated when a jamming signal is detected
NOTE: For UL Listed installations, the RF Jam feature must be enabled - Section [804], subsection [90], Option
[7] OFF.
NOTE: For DD243 installations, the RF delinquency feature should be enabled - Section [804], subsection [90],
Option [5] OFF.
NOTE: For UL Commercial Burglary Listed installations the wall and case tamper detection shall be enabled
(section [90] options 3 and 4 shall be OFF).
Option(s)
Option ON
1-2
For Future Use
3
Wall Tamper Disabled
4
Case Tamper Disabled
5
RF Delinquency Disabled
6
For Future Use
7
RF Jam Detect Disabled
8
Global Placement Test
(Valid entries = 01 - 32, 00 = RF Jam detect disabled.)
Option OFF
Wall Tamper Enabled
Case Tamper Enabled
RF Delinquency Enabled
RF Jam Detect Enabled
Individual Placement Test