WIN # READ
WRITE
228
Always
-
Always
231
-
s
234
Always
-
300
Always
-
301
Always
-
302
Always
-
307
Always
-
319
Always
-
320
Always
-
321
Always
-
322
Always
-
323
Always
-
324
Always
-
325
Always
-
362
Always
-
363
Always
-
364
Always
-
365
Always
-
366
Always
-
367
Always
-
368
Always
-
369
Always
-
TwisTorr 305-IC User Manual / 87-901-058-01
TYPE
NAME
N
Warning code
A
Standard Information Pump
N
Bus Voltage
N
Cycle time
N
Cycle number
N
Pump life
N
Controller life
A
Controller P/N
A
Pump P/N
A
Pump Special Model
A
Pump S/N
A
Controller S/N
A
Pump Modification Level
A
Controller Modific. Level
N
Average Pump Temperature
N
Average Current
N
Average Power
N
Average Frequency
N
N
N
N
Technical Information
Window Description
MEANING
This location has a bit 283ignificant:
13 = A1 THERMALFAIL
12 = A2 THERMALFAIL
11 = DO1 THERMALFAIL
10 = DO2 THERMALFAIL
9 = V24VDC WARNING UNDERVOLTAGE
8 = ANALOGOUT OUT TOLL
7 = A1 UNDERLOAD
6 = A2 UNDERLOAD
5 = DO1 UNDERLOAD
4 = DO2 UNDERLOAD
3 = A1 OVERLOAD
2 = A2 OVERLOAD
1 = DO1 OVERLOAD
0 = DO2 OVERLOAD
Merging of standard information:
1° char = Status Pump (ref.Win 205)
2°,3°,4° char = Output power (ref.Win 202)
5°,6°,7°, 8° char = Driving Frequency (ref.Win 203)
9°,10°,11° char = Body temperature (ref.Win 204)
It reads the Bus Voltage
It indicates the time of the last cycle (from the last start to
now if the pump is running)
It indicates the number of cycles start/stop during all the
pump life.
It indicates the total hours of pump life.
It indicates the total hours of controller in stand by
It is the Part Number of Controller
It is the Part Number of Pump
It is a four chars code to identify the Part Number of
special Pumps
It is the Serial Number of Pump
It is the Serial Number of Controller
It is the upgrading level of the pump
It is the upgrading level of the controller
It indicates the pump temperature filter value with T=1hour
It indicates the bus current filter value with T=1hour
It indicates the power supplied filter value with T=1hour
It indicates the driving frequency filter value with T=1hour
Worst temp cycle number
Worst temp cycle time
Worst temp cycle temperature
Worst temp cycle current
8