Settings Menu - Kessel InnoClean PLUS EQ 4 Instructions De Montage

Système de nettoyage pour les eaux usées ménagères
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 47
8.4 Setting menu
Systeminfo
Information
Informationen
Maintenance
Wartung
Positions
Einstellungen
8.4.7 Low water module
8.4.8 Pressure monitoring Continuous pressure measurement (monitoring) of the InnoClean PLUS system. The
8.4.9 Communication
8.4.10 Classes
8.4.11 Nominal sizes
8.4.12 Language
8.4.13 Reset
8.4.14 Current monitoring Continuous current measurement (monitoring) of the InnoClean PLUS system. The pre-
8. Control of the septic system
Parameter
Parameter
Parameter storage
Parameterspeicher
Date/time
Datum / Uhrzeit
Float
Schwimmer
Pressure sensor
Drucksensor
HW Modul
UW Modul
Pressure monitor
Drucküberwachung
Communication
Kommunikation
Classes
Klassen
Nominal size
Nenngrößen
Language
Sprache
Reset
Reset
Electricity control
Stromüberwachung
Switching on and off the low water alarm. The height for the alarm signal preset at the
factory is 80 cm.
preset values should not be changed. The pressure monitoring system is deactivated
by deactivating the pressure sensor (see 8.4.5)
Input / change of the station name, the device number, the modem type, the PINS and
the number of the mobile phone to which possible malfunctions can be sent via SMS
(for a detailed description see separate operating instructions).
Display / change of purification class.
Display / change of nominal size.
Display / change of language
Resetting the control unit to the factory setting (operating hours are not reset).
set values should not be changed. Current monitoring is deactivated by setting the bot-
tom current limit to 0.0 A.
8.3.3 Maintenance deadline
Input of the next maintenance deadline by the main-
tenance partner.
8.4.1 Parameters
Change of parameters stored at the factory.
Note: Every change is immediately accepted when
the OK key is pressed. In addition, on quitting this
menu it is possible to save these values in the para-
meter memory (see point 8.4.2) under a separate
name.
8.4.2 Parameter memory
Loading of the values accepted on initialisation and of
the values added under a new name (see 8.4.1).
8.4.3 Date / time
Setting the current date and time.
8.4.4 Floater
Switching the two floaters on and off (second floater
is an optional accessory). The status is displayed in
the system information menu.
8.4.5 Pressure sensor
Activation / deactivation of the pressure sensor. De-
activation deactivates the high water and low water
module and the pressure monitoring system.
8.4.6 High water module
Switching on and off the high water alarm. The height
for the alarm signal preset at the factory is 150 cm.
124

Publicité

Table des Matières
loading

Table des Matières