MASTER-SLAVE FUNCTION
The Master-Slave connection module allows you to move two synchronised
road barrier motors. The Master motor will then command the Slave motor.
Attention: All security and command devices must be connected to the Master
motor and the Slave motor must have all the security devices
bridged and the commands disconnected. Transmitters must be memorised
CP
on the Master motor. The two motors will move together in synchrony (opening,
closing etc.), particular situations (such as the intervention of the current sensor
on the Slave motor) may cause a loss of synchrony but this will be corrected
automatically through repositioning.
How to connect the motors:
- program all barrier movements on both motors as if they were independent;
- switch off the power to both ECU's, insert the Master - Slave MODCA
modules into the slots J2 on the mother board;
- interconnect the modules as shown in the drawing
paying careful attention to the crossover connection
of binding posts A and B;
- power up the programmers;
- go to
in the
MASTER/SLAVE
OPTIONS
your Master motor to MASTER; then set your
Slave motor to SLAVE;
- check that the indication 'MASTER MODE' appears
on the display start up screen of the Master motor;
- check that the indication 'SLAVE MODE' appears on
the display start up screen of the Slave motor.
REMOTE CONTROL
Each channel has a choice of 6 possible functions: open - shut - sequential com-
mand - CH2 output - stop - events on/off.
To set the functions to channels "A","B","C","D" use the command "CHANNEL
FUNCTIONS" from the "REMOTE" menu. The sequential command may be set to
"open-stop-shut-stop" or "open-close".
Memory module (MM)
This is extractable, furnished with a non volatile EEPROM type memory, contains the
transmitter codes and allows you to memorise up to 300 codes S4XX / 1000 codes
S500 series. Before memorising the transmitters for the first time remember to
cancel the entire memory content.
If the electronic card has to be replaced due to failure, the module can be extracted
from it and inserted into the new card. Make sure that the module is correctly
inserted as shown in fig. 11.
TRANSMITTER CODE MANAGEMENT
Memorising a channel
1. Scroll to the "MEMORISATION" step in the "REMOTE" menu and confirm using
the "PROG/OK" button:
the indication "Activation 1" will flash on the LCD.
2. Activate the transmitter channel that is to be memorised:
the indication "Activation 2" will flash on the LCD.
3. Activate the transmitter again (same transmitter, same channel
the indication "Code memorised" will flash on the LCD.
The number of channels already present in the memory is shown on the first line
in brackets.
*
if the channel is different or it is a different transmitter (point three) the memorisation
attempt will abort without success however "Activation 1" will still flash on the LCD.
Note: It is not possible to memorise a code which is already in memory: if you attempt
this the indication "COD. IN MEM." (point one) will appear on the LCD.
Cancelling a channel:
1. Scroll to the "CANCELLATION" step in the "REMOTE" menu and confirm using
the "PROG/OK" button:
the indication "Activation 1" will flash on the LCD.
2. Activate the transmitter channel that is to be cancelled:
the indication "Activation 2" will flash on the LCD.
3. Activate the transmitter again (same transmitter, same channel
the indication "Code cancelled" will flash on the LCD.
The number of channels already present in the memory is shown on the first line
in brackets.
*
if the channel is different or it is a different transmitter (point three) the cancellation
attempt will abort without success however "Activation 1" will still flash on the LCD.
Note: It is not possible to cancel a code which is not already in memory: if you attempt
this the indication "COD. NOT MEM." (point one) will appear on the LCD.
Cancelling all user codes from memory:
1. Scroll to the "CANCEL ALL MEMORY" step in the "REMOTE" menu and confirm
using the "PROG/OK" button: a procedure confirmation request "CANC ALL
MEMORY?" will appear on the LCD (press one of the arrows to exit the procedure).
2. Press the "PROG/OK" button to confirm the total cancellation:
the indication "CANCELLING" along with a progress bar will appear on the
display.
3. Once the total cancellation has been carried out the display will return to "CANCEL
ALL MEMORY".
-
-
TB
FS
FI
menu and set
A B C
A B C
MASTER
SLAVE
*
):
*
):
Memorising ulterior channels via radio (S4XX transmitters)
• The system can be remotely activated using radio control devices; (without opening
the receiver) by setting "MEMO RADIO" has been activated in the "OPTIONS"
menu.
-
1. Using a transmitter, in which at least one channel
button "A, B, C or D" has already been memorised
in the receiver, press the button in the transmitter as
shown in figure.
Note: all the receivers within range when the channel button is pressed (and which
have at least one of the transmitter channel buttons memorised) will activate their signal
buzzer "B1" (fig. 11).
2. Press one of the channel buttons on the same transmitter. The receivers which do
not contain that channel code will sound a five-second long "beep" and will then
deactivate. The receivers which contain the channel code will sound a one-second
long "beep" and will enter the "programming via radio" mode.
3. Press the previously chosen channel buttons on the transmitter which you wish to
memorise; the receiver will sound 2 "beeps" of half a second each after which the
receiver will be ready to receive another code.
4. To leave the programming mode wait for 3 seconds without pressing any buttons.
The receiver will sound a five-second long "beep" and will then exit the programming
mode.
Note: When the memory is entirely occupied the buzzer will sound 10 rapid "beeps"
and will automatically leave the "programming via radio" mode.
The same signal is given each time you try to enter "programming via radio" when
the memory is full.
Note: the memo radio procedure can only be carried out after programming has
terminated and you have quit the setting/programming menu.
Memorising more transmitters by using a previously memorised
transmitter S504 - S508
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
This procedure allows you to enable a new transmitter (from a remote position) with the
help of a transmitter that has already been memorised in the system. As the presence of
the receiver is not required this procedure can be carried out in any remote location (for
example in your chosen sales outlet).
Access to the 'rapid memorizing' procedure is possible if the
parameter 5p has been activated via the menu
• Remove the upper cover from the transmitter to be memorised and from the transmitter
that has already been memorised as shown in the drawing below (det. a).
• Place the transmitter A, that has already been memorised in the receiver, beside the new
transmitter B (det. b).
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
• Using a pointed object press and release the MR button on both transmitter (in
sequence or simultaneously).
• The orange LEDS on the transmitters will flash slowly.
• Press and release a channel button on transmitter A that is already present in the
receiver (det. c).
• The LED of the new unit B will remain lit for 3 seconds to confirm that the transmitter has
been accepted (det. d).
Transmitter B will now command the receiver exactly like transmitter A.
1
3
2
CONNECTING THE ANTENNA
Connect an ANS400 / ANQ800-1 tuned antenna using a coaxial cable RG58 (imped-
ance 50Ω) with a maximum length of 15 m.
FUNCTION MODES
Description :
Drawing number :
DM0910
1) Automatic
Product Code :
TRQ504
Selected by enabling automatic reclosing (Automatic reclosing "ON" on the display).
Draft :
P.J.Heath
Date :
29-10-2013
When the boom is completely closed the opening command will start a complete cycle
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
which will end with automatic reclosing.
Automatic reclosing starts after the programmed pause period has elapsed (minimum
2 seconds) when the opening cycle has been completed or straight away after the
Drawing number :
DM0911
intervention of a photoelectric cell (the intervention of a photoelectric cell causes the
Product Code :
TXQ504C4
pause time to be reset). During the pause time "Pause" will flash on the display along
Draft :
P.J.Heath
Date :
29-10-2013
with the remaining pause time.
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
Pressing the blocking button during this period will stop automatic reclosing and
consequently stop the display from flashing. The indicator light remains lit until the
closing manoeuvre has terminated.
25
Description :
Drawing number :
DM0531
Product Code :
RCQ449100
Draft :
P.J.Heath
Date :
13-04-2001
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
REMOTE MEMORISE
on the electronic programmer.
OPTIONS
All rights reserved. Unauthorised copying or use of the information contained in this documen
MR
MR
A
B
B
A
MEMORIZZAZIONE CODICE TX-TX
Description :
MEMORIZZAZIONE CODICE TX-TX
Drawing number :
DM0912
Description :
TXQ504C4
MEMORIZZAZIONE CODICE TX-TX
Product Code :
Date :
Draft :
P.J.Heath
29-10-2013
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 04