Télécharger Imprimer la page

Cardin Elettronica ELDOM346 Série Manuel D'instructions page 23

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27
• Set the main operating parameters (e.g. installation right/left) in the options menu.
• If you have safety devices working with 8.2k contacts select the correct setting from the safety device menu.
• Before programming the boom travel distances select the correct motor in the "Motion" menu.
OPTIONS
SAFETY DEVICES
MOTION
Arrow
DISPLAY
to
CALENDAR
scroll
REMOTE
"PROG/OK"
to confirm
SET TIME
08:00
SET DATE
"PROG/OK"
23-12-13
to change
the value
SET EVENTS
SET TIME
08:00
"PROG/OK"
SET DATE
to change
23-12-13
the value
SET EVENTS
SET TIME
08:00
SET DATE
23-12-13
"PROG/OK"
SET EVENTS
to confirm
EVENT 0
SET DATE
MO-SU 08-10 TA 1
23-12-13
EVENT 1
SET EVENTS
MO-SU 08-10 TA 1
EVENT 2
EVENTS: ON/OFF
MO-FR 10-08 TA 0
EXIT
Note: 12
SET EVENTS
"PROG/OK"
to return to the
EVENTS: ON/OFF
calender menu
EXIT
6)
Aux1 - Aux2:
- closed / open - aux 1 = closed barrier signal - aux 2 = open barrier signal;
- ch2 / courtesy light - aux 1 = enables the second channel by radio - aux 2 = contact for courtesy light;
- closed / courtesy light - aux 1 = closed barrier signal - aux 2 = courtesy light.
7)
Setting the current sensor:
-
Level 1 = motor input + 2 amps
-
Level 2 = motor input + 3 amps
-
Level 3 = motor input + 4 amps
-
Level 4 = motor input + 5 amps
-
Level 5 = motor input + 6 amps
When the sensor is activated the boom immediately reverses movement for approximately 10 cm, whether it was opening or closing, so that the obstacle is
freed; it then remains at a standstill for 3 minutes,after which there is a pre-blinking stage of 10 seconds before the boom starts moving again in the same
direction as when movement was interrupted.
8)
Braking when closing:
When the boom is closing, it decelerates noticeably just a few degrees before gently ending the manoeuvre. The parameter controls the distance from the clos-
ing stop point at which this deceleration occurs. The value "9" means that the final deceleration starts well before the closing stop point. The factory-set default
value of "2" normally satisfies almost all situations
9)
Deceleration in closing / opening:
These 2 parameters control the starting point for the boom deceleration. A higher number means more space for slowing down, whereas a lower number means
less space. Before starting a movement, check the spring is balanced since the default values are calibrated for best movement
10) Setting the distance from the closing/opening stop point:
To increase or decrease this distance, set the parameter to anywhere between 0 and 9. Set at "0",the boom will stop very near the stop point, at "9" the boom
will stop further away from the stop point.
11) Closing speed:
The parameter controls the overall closing speed, "1" = max. speed "2" = med. speed "3" = min. speed
12) On/Off events:
By setting the On/Off function on one of the radio channels, it is possible to activate/deactivate the events by remote control. Activation is indicated by the
flashing light blinking for 6 seconds and by the warning light. Deactivation is indicated by the light blinking for 3 seconds.
13) Coding: Before changing the type of coding, it is necessary to change the storage module from S4XX to S500 or vice versa, having first cut off the electricity
supply to the control unit.
14) Channel functions
Each radio control channel can be "A","B","C","D" set to one of 6 available functions:
- TD sequential command; TA open; TC close; Block; CH2 second radio channel; events on/off
OPTIONS
SAFETY DEVICES
MOTION
Arrow
Arrow
DISPLAY
to scroll
to exit
CALENDAR
REMOTE
"PROG/OK"
"PROG/OK"
to confirm
to toggle the
ENCODING: S4XX
value between
MEMORISE
S4XX & S500
CANCEL
Note: 13
CLEAR ALL MEMORY
CHANNEL FUNCTION
EXIT
ENCODING: S4XX
"PROG/OK"
MEMORISE
to confirm
CANCEL
CLEAR ALL MEMORY
CHANNEL FUNCTION
EXIT
ENCODING: S4XX
MEMORISE
"PROG/OK"
CANCEL
to confirm
CLEAR ALL MEMORY
CHANNEL FUNCTION
EXIT
ENCODING: S4XX
MEMORISE
CANCEL
"PROG/OK"
CLEAR ALL MEMORY
to confirm
CHANNEL FUNCTION
EXIT
ENCODING: S4XX
MEMORISE
CANCEL
CLEAR ALL MEMORY
"PROG/OK"
CHANNEL FUNCTION
to confirm
EXIT
ENCODING: S4XX
"PROG/OK"
MEMORISE
to return to
CANCEL
the remote
menu
CLEAR ALL MEMORY
CHANNEL FUNCTION
EXIT
Language choice:
• Press the right and left buttons
simultaneously to enter the
language submenu.
• Press the right and left buttons
to change the language: Italian
to English.
• Press the "PROG/OK" button
to con rm the choice.
MEMORISE
MEMORISE
PRESS the
[Nr...]
transmitter
* * * * * * * * * * * * * * *
channel
* * * * * * * * * * * * * * *
[AB--]
*
*
to memorise
*
* ACTIVATION 1
*
* ACTIVATION 2
*
*
*
* * * * * * * * * * * * * * *
* * * * * * * * * * * * * * *
CANCEL
PRESS the
[Nr...]
transmitter
* * * * * * * * * * * * * * *
* * * * * * * * * * * * * * *
channel
[AB--]
*
*
to memorise
*
* ACTIVATION 1
*
* ACTIVATION 2
*
*
*
* * * * * * * * * * * * * * *
* * * * * * * * * * * * * * *
EXIT
* * * * * * * * * * * * * * *
* * * * * * * * * * * * * * *
CANCEL
* CANCELLING
*
*
* ALL MEMORY ? *
* * * * * * * * * * * * * * *
PRESS ok to
* * * * * * * * * * * * * * *
cancel all
memory
OK
or press exit
CHANNEL A
Note: 14
channel function A
CHANNEL B
"PROG/OK"
to change
channel function B
the value
CHANNEL C
channel function C
CHANNEL D
channel function D
EXIT
23
PROGRAM
ITALIANO
TB FI
TA TD
FRANÇAIS
FS CP
TC
ENGLISH
NEDERLANDS
DEUTSCH
00.000.007
ESPAÑOL
07-06-13 15.35
"PROG/OK" to confirm
press both arrows
simultaneously to enter
the language submenu
MEMORISE
PRESS the
[Nr...]
[Nr...]
the same
transmitter
* * * * * * * * * * * * * * *
[AB--]
[AB--]
channel
*
*
again
CODE
*
*
MEMORISED
*
*
* * * * * * * * * * * * * * *
CANCEL
CANCEL
PRESS the
[Nr...]
[Nr...]
the same
* * * * * * * * * * * * * * *
transmitter
[AB--]
[AB--]
channel
*
*
CODE
again
*
*
CANCELLED
*
*
* * * * * * * * * * * * * * *
*
*
*
*
*
*
*

Publicité

loading

Ce manuel est également adapté pour:

Eldom34-6lgEldom34-6dg