16
Symbols
Read the Operating Instructions
Before carrying out any work on the machi-
ne, disconnect the plug from the socket.
Cable pullying / transport prohibited
Staying in the transportation medium
prohibited
Warning against dangerous electric
voltage
Inspection and maintenance plan
Time interval
As needed
Failures – causes - removal
Failures
Engine does not start
Pump does not suck
Thermal detector swit-
ching the pump off
4
Insufficient amount of
water pumped
Description
Clean the foot valve.
Causes
No nework voltage.
Pump wheeel is blocked.
Missing, untight or blocked foot valve
Foot valve is not in water.
No water in the pump shell.
Too high suction height.
Air bubbles in suction pipeline.
Connections not sealed, the pump sucks the
air, the pump is not bleeded.
Prefilter clogged
Pump if overheated and switched off by the
thermal overloading protection.
Electric power missing.
Impurity particles (e.g. pebbles) have settled
down in the suction hole.
Too high suction height.
Foot valve suction basked dirty
Prefilter dirty
Water level drops quickly.
Warning against automatic starting
Accessory - Not included in standard
equipment, available as an accessory.
Any damaged or disposed electric or
electronic devices must be delivered to
appropriate collection centres.
Protect against humidity
This side up
Any other details
Check the foot valve function
Removal
Check the voltage.
Turn the engine shaft with screwdriver
through the fan cover (to release friction
circles sealing that may be stuck together)
Assembly or clean the foot valve.
Immerse the foot valve into water.
Fill the pump shell with water.
Check the suction height.
Check the tighting of suction pipeline.
Carefully repeat connection according to
chapter „
"!
SUPPLY
Clean the prefilter
10
Let the device getting cool!
Check power supply
Disassamble and clean the susction hose,
prevent suction of foreign substances.
Check the suction height.
Clean tne suction basket.
Locate the foot valve lower.
Clean the prefilter
10
Clean the pump and replace worn parts.