Hostname (binary
DNS host name or IP address of the
OCPP)
binary OCPP proxy server for the
Backend-System
Port number (binary
TCP port of the proxy server for
OCPP)
binary communication with the
Backend-System
WebSockets JSON
WS / WSS-URL of the OCPP
OCPP URL of the
Backend-System
Backend
WebSockets keep-
WebSockets keep-alive interval (in
alive interval
seconds)
HTTP Basic
Password for HTTP Basic
Authentication pass-
Authentication
word
Tcp Watchdog
Time until a restart will be exe-
Timeout
cuted, after the connection to the
Backend-System has been inter-
rupted or could not be restored
Enable cache
Setting that specifies whether an
internal cache will be used for the
RFID-UID
List of entries in
Listing of the RFID-UIDs present in
cache
the internal cache
Cache expiry mode
The expiration date of cache ent-
ries, if the OCPP expiration date has
not been specified by the Backend-
System
Cache learning mode
Activates the teaching of RFID UIDs
via the RFID card reader. The ent-
ries are stored in the internal cache.
Local fixed authoriza-
Setting that specifies whether a
tion list (FLL)
local authorization list will be used
for the RFID-UIDs
List of entries in FLL
Listing of the RFID-UIDs in the local
authorization list
FLL learning mode
Activates the teaching of RFID UIDs
via the RFID card reader. The ent-
ries are stored in the local authori-
zation list.
This setting input box must remain empty
Charging
system
Preset: "444"
Only for "OCPP-J 1.6".
ID of the charging point is automati-
cally attached when connecting to the
Backend-System
The value "0" prevents the keep-alive
Backend-
interval
System
Information will be provided by your
Backend-System provider
An empty field prevents the HTTP
Basic Authentication.
Information will be provided by your
Backend-System provider
The value "0" prevents a restart of the
Charging
device
system
"Off": RFIDs will not be added to the inter-
nal cache
Syntax: UID1:UID2:UID3 ...
Max. 80 RFID-UIDs
Preset: 2038 (latest permissible time)
The function remains active for 5 minutes
Authori-
zation
Syntax: UID1:UID2:UID3 ...
Max. 80 RFID UIDs are displayed
The function remains active for 5 minutes
EN