24
WIRELESS REMOTE CONTROL
Wireless remote control (RC) duplicates the POWER ON function, digital
zoom, distance measurement, and menu navigation.
RC controls are:
Controller (18)
Button ON (15) Button ZOOM (16) Button LRF (17)
Short press Enter quick menu Turn sight on /
Calibrate
sensor
Long press Enter main menu Turn display /
sight off
Clockwise
Increase value,
rotation
upward
movement
Counter-
Decrease value,
clockwise
downward
rotation
movement
25
Maintenance should be carried out no less frequently than twice a year,
and should consist of the following measures:
Wipe external plastic and metal surfaces clean of dust and dirt with a
soft cloth moistened with a synthetic cleaning agent.
Clean the electric terminals of the Battery Pack and sight's battery slot
using a grease-free organic solvent.
Check the objective and eyepiece lenses. If required, remove dust
and sand (preferably by a noncontact method). Clean the external
surfaces of the lenses with products expressly designed for this
purpose.
Always store the sight in its carrying case in a dry, well-ventilated
space. For prolonged storage, remove the batteries.
6 31
Activate
Measure
incremental
distance
zoom
Turn on/off
Wi-Fi on/off
PiP
SCAN mode
17
16
15
18
26
Check:
External view (there should be no cracks on the housing).
The state of the objective and eyepiece lenses (there should be no
cracks, spot, dust, deposits etc.).
The state of the Battery Pack (should be charged) and electric
terminals (there should be no oxidation).
Correct functioning of the controls.
27
TROUBLESHOOTING
The table presented below lists some potential problems that may occur
when using the sight. If a problem encountered with the sight is not listed,
or if the recommended action does not resolve the problem, the unit
should be returned for repair.
Problem
Check
The thermal sight
Battery Pack is discharged.
will not turn on.
The sight does not
USB cable is damaged.
operate on external
External power supply is
power supply.
discharged.
The image is blurry,
Calibration is required.
with vertical stripes
and uneven
background.
The image is too
dark.
The reticle is blurred
The dioptre cannot be
and cannot be
adjusted to your eyesight.
focused with the
dioptre knob.
Corrective action
Charge the battery.
Replace USB cable.
Charge the external power
supply (if necessary).
Carry out calibration according
to Section "SENSOR
CALIBRATION".
Adjust brightness/contrast with
the UP/DOWN buttons.
If you wear prescription glasses
with a range of +/- 4, keep
glasses on when looking
through the eyepiece.