Check that the seal is on the probe.
→
Install the 8221 with clamp connection 2 onto the clamp of the
pipe 1.
→
Place the clamp together.
→
Fix the clamps with the flange clamp 3.
Fig. 13: Installation of a 8221 clamp connection
7.2.4.
installation of a 8221 with 2"
(Dn50/40) connection
The 8221 probe with 2" (DN50/40) connection is mounted onto the
GEA Tuchenhagen VARINLINE process connections to the appro-
priate dimensions.
Type 8221
Installation
3
2
1
7.2.5.
installation of a 8221 with pG13.5
connection
The probe 8221 with PG13.5 connection is mounted onto a holder:
• 8200 direct welding holder (see 7.2.6);
• 8200 hygienic holder with G1¼" threaded connection (see 7.2.7);
• 8200 hygienic holder with clamp connection (see 7.2.8).
To install the holder, refer to the 8200 direct welding holder
and to the 8200 hygienic holder using manuals.
7.2.6.
installation of a 8221 with pG13.5
connection onto a direct welding
holder
The holder is intended only for mounting probes with a
length of 120 mm.
Make sure the welded area has cooled down before
inserting the probe.
English
17