4.2 Remote control commands
Object
& Root
Mode
: ├
Select
.
.Name
.Parameter
│ ├
CtrlPara
.
│ │ ├
.EP
│ │ ├
.Control
│ │ ├
.Content
│ │ ├
.Special
│ │ │ ├
.Dyn
│ │ │ ├
.MaxRate Maximum rate
│ │ │ ├
.MinRate
│ │ │ ├
.Stop
│ │ │ │ ├
.Type
│ │ │ │ ├
.Drift
│ │ │ │ ├
.RelDrift Relative stop drift
│ │ │ │
│ ├
TitrPara
.
│ │ ├
.Direction
│ │ ├
.Pause
│ │ ├
.ExtrT
│ │ ├
.StartDrift
│ │ ├
.Ipol
│ │ ├
.PolElectrTest Test for polarized electrodes
│ │ ├
.Temp
│ │ ├
.TDelta
│ │ ├
.TMax
│ ├
Statistics
.
│ │ ├
.Status
│ │ ├
.MeanN
│ │ ├
.ResTab
│ │ │ ├
.Select
│ │ │ ├
.DelN
│ │
Presel
.
│ │ ├
.Cond
│ │ ├
.DCor
│ │ │ ├
.Type
│ │ │ ├
.Value
│ │ ├
.IReq
│ │ ├
.SReq
│ │ ├
.ReqTitr
│ │ ├
.SampleUnit
│ │ ├
.LimSmplSize Limits for sample size
│ │ │ ├
.Status
│ │ │ ├
.LoLim
│ │ │ ├
.UpLim
│ │ ├
.Id1Text
│ │ ├
.Id2Text
│ │ ├
.Id3Text
62
&Mode
Description
Mode
Mode selection
Name of current method
Parameters of current mode
Control parameters
Endpoint
without meaning
without meaning
Parameters for setting "special"
Dynamics
Minimum rate
Stop criterion
Type of stop criterion
Stop drift
Titration parameters
Titration direction
Waiting time before titration
Extraction time
Max.Drift for start of titration
Polarization current
Titration temperature
Time interv. for meas.acquisition
Maximal titration time
Statistics
Status of statistics calculation
No. of individual determinations
Result table
Deletion of individual results
Preselections
Conditioning
Drift correction
Type of drift acquisition
Drift value for manual drift corr.
Request of Id's after start
Request of smpl size after start
Titration during requests
Unit of sample size
Status of limit control
Lower limit
Upper limit
Text instead of Id1
Text instead of Id2
Text instead of Id3
Input range
$G, $S
KFC,KFC-B,BLANK,GLP
read only/read+write
0...50...±2000
content, special
0...70...2000
1.5...2240, max.
0.3...15...999.9, min.
drift, rel.drift
1...5...999
0...5...999
-
+,
, auto
0...999 999
0...999 999
1...20...999
2, 5, 10, 20, 30
ON, OFF
-170.0...25.0...500.0
1...2...999 999
1...999 999, OFF
ON, OFF
2...20
original,delete n,delete all
1...20
ON, OFF
auto, man., OFF
0.0...99.9
id1, id1&2, all, OFF
value, unit, all, OFF
ON, OFF
g, 5 ASCII
ON, OFF
0.0...999 999
0.0...999 999
up to 10 ASCII char
up to 10 ASCII char
up to 10 ASCII char
756/831 KF Coulometer, Instructions for Use
Reference
4.2.2.1.
4.2.2.2.
4.2.2.3.
4.2.2.4.
4.2.2.5.
ditto
ditto
ditto
ditto
ditto
ditto
4.2.2.6.
4.2.2.7.
ditto
4.2.2.8.
4.2.2.9.
ditto
4.2.2.10.
4.2.2.11.
4.2.2.12.
4.2.2.13.
ditto
ditto
ditto
4.2.2.14.
ditto
ditto
4.2.2.15.
ditto
ditto
4.2.2.16.
4.2.2.17.
ditto
ditto
ditto
4.2.2.18.
ditto
ditto