OPERATING LIMITS of the unit:
Maximum entering water temper-
ature:
80°C
Maximum operating pressure:
8bar
Space temperature limits (Ta):
0°C < Ta < 40°C
Space relative humidity limits
(%RH):
%RH < 85%
Power supply:
110/240v ~ 50/60Hz
Protective rating:
IP20
1.

GENERAL WARNINGS

The AERMEC VED_I units are manufac-
tured in accordance with recognised
technical standards and safety regula-
tions. They are designed for the renewal
and treatment of ambient air, and they
must be used for the purpose for which
they are intended and their performance
characteristics. All contractual and extra-
contractual liabilities causing damage to
persons, animals or objects or through
errors of installation, control or mainte-
nance or from improper use are excluded
by the Company. Any uses not expressly
indicated in this manual are not permit-
ted.
1.1.
CONSERVATION OF DOCUMENTA-
TION
Consign the instructions with all the com-
plementary documentation to the user of
the accessory who will assume responsi-
bility for the conservation of the instruc-
tions so that these are always available in
case of need.
Carefully read this document. The execu-
tion of all the works must be carried out
by qualified personnel, in accordance
with the national regulations.
It must be installed in such a way to make
maintenance and/or repair functions
possible.
Do not modify or tamper with the acces-
sory as this may cause danger for which
the manufacturer will not accept any
responsibility for damages caused. The
warranty is voided if the above instruc-
tions are not followed.
1.2.
SAFETY WARNINGS AND INSTALLA-
TION STANDARDS
2.

PRODUCT IDENTIFICATION

The VED fan coil units are identified by:
− PACKING LABEL
that records the product identification
data.
− NAMEPLATE
− The unit must be installed by a com-
petent and qualified technician, and
in accordance with the legislation ap-
plicable in the country of installation.
Aermec assumes no responsibility for
damage caused by failure to observe
these instructions.
− Instructions essential for the proper in-
stallation of the equipment are shown
here. The final details to all the opera-
tions are left to the experience of the
installer in accordance with the specific
needs.
− Before commencing any works it is
necessary to CAREFULLY READ THE IN-
STRUCTIONS AND MINIMISE ANY RISKS
BY TAKING APPROPRIATE SAFETY PRE-
CAUTIONS.
− All relevant personnel must be made
aware of the procedures and possible
risks that may arise at the time of instal-
lation of the unit.
− The unit must be installed in such a way
as to make easy ordinary maintenance
(filter cleaning) and special mainte-
nance as well as access to the heat ex-
changer.
−WARNING! : It is absolutely forbidden
the operate the unit without connecting
to the ducting system.
− DANGER : The fan is located immediately
beneath the nozzles. It is absolutely for-
bidden to insert hands or objects. Pow-
er the unit only after connecting to the
ducting system.
WARNING: The tampering, re-
moval or absence of the identifi-
cation label renders difficult any
operation of installation or main-
tenance.
4880950_03 - 1811
21