OPERATOR´S MANUAL
4.4 Preparing installation for wooden-
pools
Modifying the installation kit
Cut the chase, Ø 260 and drill the securing bo-
res Ø 12 in the pool wall, refer to the drill pattern
in Fig. 14.
Note: The clamp ring Pos.68 must be used as a
template.
Pay attention to the asymmetrical position of the
drilled holes!
(Fig. 14)
4.5 General installation
If the motor is mounted on a metal support, insu-
late it against the ground to avoid transmission of
external voltage onto the unit and the water in
the swimming pool.
4.6 Installation pump kit I for concrete
tile pools
Mount the suction housing (10) with the flat gas-
ket (32) and the nuts (26) and the washers (27)
onto the installation kit (20). The sealing sur-
faces must be clean and smooth.
Note: The housing (10) must be mounted so that
the connection for the membrane switch (MS) is
at the top.
(Abb. 16)
C2 - rondo
Version: 27200 - B
NOTICE D´ÚTILISATION
4.4 Préparatifs pour l'encastrement de
bassins en bois
Adaptation du lot de montage
Percer la réservation Ø 260 et les trous de fixati-
on Ø 12 dans la paroi du bassin, cf. schéma à la
fig. 14.
Remarque: utiliser la rondelle pos. 68 comme
gabarit.
Tenir compte que les trous ont une disposition
asymétrique !
(Fig. 14)
4.5 Généralités sur le montage
Si le moteur est monté sur un support métallique,
l'isoler contre le sol pour éviter la transmission
de tension parasite sur l'appareil et l'eau du bas-
sin.
4.6 Montage de l'unité de base I pour
bassins en béton carrelés
Monter le corps d'aspiration (10) avec le joint plat
(32) et les écrous (26) et les rondelles (27) sur le
lot de montage (20). Les jointures doivent être
propres et lisses.
Remarque: monter le corps (10) de façon à ce
que le branchement de l'interrupteur à membra-
ne se trouve sur le dessus.
(Abb. 16)
Schmalenberger GmbH + Co.
D-72013 Tübingen - Germany
19