IMPORTANT NOTES
Pre-heater thermostats substitution.
Replace the probe of the new thermostat, after loosening
the fixing screws of the plate pack, making sure there is a
good contact between the probe and the pipes and the re-
sistor, see the drawing opposite. The same precautions
should be taken when renewing the resistors in contact
with the thermostat probes.
Should exceptional changes or excessive temperatures
be detected during operation, verify the continuity of the
resistor in contact with the temperature probe using an
ohmmeter (approximately 35 Ohm).
Only use filters with a groove on the tightening hex head.
NOTE
The pre-heater might be fitted with a second maximum value thermostat with a manual reset.
This thermostat can be used to act as a switch on an external contact maker to cut off the current to the pre-
heater if the temperature is too high (kit code no. 3000800).
Before the burner start-up, verify that the pump is filled with fuel in order to prevent it functioning while empty
for too long.
Filter cleaning:
periodically clean the filters so the burner always works properly.
Supply line filter:
positioned on the suction line, it causes the increase of the vacuum in the pump making it noisier. Do not ex-
ceed the vacuum of 45 cm Hg (6 m W.c.) (5, fig. 1).
Pre-heater filter (10, fig. 1):
positioned in the delivery line, it causes a decrease in the atomisationing pressure which is monitored with a
manometer (12, fig. 1).
MANOMETER PROTECTION VALVE
After the atomisation pressure check, turn off the manometer (12, fig. 1) to avoid pressure shocks that it might
be subject to each time the burner is started up.
For this reason close the protection valve when the burner is not working and the manometer indicates 0 bar.
4.7
BURNER START-UP PROGRAMME
Normal
Thermostat
Motors
Ignition transformer
st
1
flame valve
nd
2
flame valve
Lock-out indicator
Motor lock-out
It is caused by the thermal motor overload relay if an overload occurs or there is no phase.
6195
Plate
D2751
Lock-out because of no ignition
9
GB
Pipes into aluminium plate
Resistor
Thermostat probe
2894