3 Product description
Equipment features
Charging powers up to 7.4 kW (single-phase) / 22 kW
(three-phase).
Communication between device and vehicle according
to ISO 15118. *
Authorisation via Backend-System or RFID card
(ISO 14443A / MIFARE classic and MIFARE DESFire).
Integrated modem for mobile network standards 4G
(LTE), 3G (UMTS) and 2G (GSM).
Compatible with OCPP 1.5 and OCPP 1.6.
MENNEKES ECU, Electronic Control Unit.
Status information via LED information panel.
Integrated MiD energy meter.
Circuit breaker. *
Type A residual current device. *
DC residual current monitoring > 6 mA.
Integrated shunt release (for welding detection). *
Relay for connection of an external shunt release (for
welding detection). *
Unlocking function in the event of a power failure (only
for devices with Type 2 charging socket).
Phase sequence relay. *
Temperature monitoring.
Integrated cable storage.
Wired ready for connection.
*optional
Optional equipment
Communication according to
ISO 15118
Circuit breaker
Type A residual current device
Shunt release
Relay for shunt release
Phase sequence relay
6
3.1
The type plate contains all important device data. The
type plate shown is an example.
f Note the type plate on your device. The type plate is
Fig. 1: Type plate (pattern)
1. Manufacturer
2. Type
3. Item / serial number
4. Rated current
5. Rated voltage
6. Rated frequency
7. Standard
8. Barcode
9. Number of phases
10. Degree of protection
11. Information
-
-
x
-
x
x
-
x
x
-
x
x
x
-
-
-
x
x
Type plate
located at the top on the underpart of the enclosure.
1
XXXXXXXXX
2
Typ.SN:
3
I
: xx A
4
nA
U
: xxx V ~
5
n
f
: xx Hz
6
n
IEC 61851, DIN IEC/TS 61439-7
7
8
xxxxxxxx.xxxxx
xP+N+
9
IPxx
10
AEVCS
11