The wire which is coloured Green-and-Yellow
must be connected to the terminal in the plug
which is marked with the letter E or by the symbol
or coloured Green or Green-and-Yellow. The
wire which is coloured Blue must be connected
to the terminal which is marked with the letter N
or coloured Black. The wire which is coloured
Brown must be connected to the terminal which
is marked with the letter L or coloured Red.
* Should the socket outlets in the installation site
not be suitable for the plug supplied with your
product, the plug must be removed (cut off if it is
moulded on plug) and an appropriate plug fitted.
If the non-rewirable plug has been cut from the
power supply cord, it must be disposed of. There
should be no attempt to reuse it. Inserting such a
plug into a socket elsewhere presents a serious
risk of electrical shock.
* The non-rewirable plug must never be used
without a fuse cover being fitted.
The correct replacement for the detachable fuse
cover is identifiable from the manufacturer's
reference number stamped on the plug.
Supply of replacement fuse covers can be
obtained from Hoshizaki Parts/Service Centres.
Fuses should be rated at 12A and approved to
BS 1362.
3. WATER SUPPLY AND DRAIN
CONNECTIONS
WARNING
Connect to potable water supply only.
Note: A plumbing permit and services of a licensed
plumber may be required in some areas.
* The connections to the mains water supply
must be made in accordance with the countries'
current requirements of the Water Supply or
Water Fittings Regulations.
* I c e m a k i n g w a t e r m u s t b e p o t a b l e w a t e r.
Where scaling can be caused by water quality,
installation of an external filter or softener
is recommended. Contact your local water
treatment professional or Hoshizaki service
agent.
* Water supply pressure should be minimum 0.05
MPa (0.5 bar) and maximum 0.8 MPa (8 bar).
If the pressure exceeds 0.8 MPa (8 bar), use a
proper pressure reducing valve. Do NOT throttle
back the supply tap.
* The icemaker drain is gravity flow, so ensure
drain pipe has an adequate pitch or fall.
* Water should drain into an open trap.
* Drain lines should not be piped directly to the
sewer system. A vertical air gap of a minimum
of 5 cm should be between the end of the drain
pipes from the icemaker and the storage bin and
the floor drain.
* Water supply connection is intended to be made
by means of a pipe, not a hose set.
Water Supply
Inlet G3/4
Water Supply Line
Shut-off Valve
Drain Valve
Separate piping to approved
drain. Leave a 5cm vertical
air gap between the end of
each pipe and the drain.
Floor
Fig. 10
6. START-UP PROCEDURE
1) C h e c k t h a t t h e p o w e r s u p p l y c o r d i s
disconnected.
2) Move the operation switch on the operation
panel to the "ON" position.
3) Open the water supply tap.
5
ENGLISH
Drain Outlet
R3/4
Bin Drain Outlet
3/4 FPT
5cm air gap
Drain