Télécharger Imprimer la page

Güde 225/08/24 Traduction Du Mode D'emploi D'origine page 15

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
F
Compressor gets started too
often
G
Safety valve blowing off
H
Compressor getting warm
too much
I
Compressor being
overheated and keeps
switching off
Servicing table
Servicing intervals apply to standard operating conditions. Intervals are adequately shortened for extreme
operating conditions.
Steps
Suction filter check
• Cleaning
• Replacement
Check valve and insert cleaning
Condensate draining from the air jet
Condensate draining from the filter pressure
control valve
Filter insert cleaning
Compressor cleaning
Screwing check
Too much condensate in the air jet
Compressor is overloaded
Pressure in the air jet exceeds the set
cut-off pressure
Safety valve is defective
Air supply is not sufficient
Cooling fins on the cylinder (cylinder
head) are dirty
Too long time of appliance operation
Compressor is overloaded
Compressor is defective
Compressor under undervoltage
Outdoor temperature of 35°C
Intervals
Weekly
Every 50 hours of operation
At least once a year
Annually
Whenever the appliance was used
Whenever the appliance was used
As needed
As needed
After 10 hours of operation for
the first time
Then every 500 hours of
operation
Drain the condensate
Have the pressure switch adjusted/replaced by an
authorised person (Güde service centre)
Replace the safety valve or contact the Güde service
centre
Make sure sufficient air supply and outlet (minimum
distance from wall is 40 cm) is provided
Clean the cooling fins on the cylinder (cylinder head)
Switch the compressor off
Contact the Güde service centre
Contact the Güde service centre
Contact the Güde service centre
Contact the Güde service centre
Date
15
Date
Date
Date

Publicité

loading

Ce manuel est également adapté pour:

50035