At regular intervals
•
Check whether all bolts are tightened.
•
Release condensate from the air jet at regular
intervals (at least on a monthly basis).
Condensate may get brown due to the
condensate surface.
Proceed as follows:
1.
Unplug the appliance!
2.
Open the drain valve (10) at low pressure in the air
jet (max. 1 bar) and drain the condensate to the full
extent (appropriate vessel to be used).
3.
Close the valve.
Air filter
The air filter needs to be cleaned from time to time.
Remove the bolts from the cover and take out the foam
filter. The filter can be cleaned using warm lye soap. Dry
the foam filter and refit it. Attach the cover again.
Important instructions
Pressure relief not working
The pressure relief is deactivated as a result of
appliance being unplugged or system voltage drop
when the compressor is on.
Failure
A
Compressor not starting after
being switched on
B
After reaching the closed
pressure, the compressor
runs or buzzes for a short
time and then switches off
automatically
C
Compressor running
constantly
D
Compressed air is released
from the discharge valve
under the pressure switch
when the appliance is being
operated
E
After reaching the cut-off
pressure, air is released from
the discharge valve under the
pressure switch until the
closing pressure is reached
Cause
Pressure in the air jet exceeds the
closing pressure
Defective supply
Defective pressure switch
Worn carbons
Electric cable is too long or its cross
section is too small
Suction filter is very dirty
Pneumatic tools have high air
consumption
Leaking on the compressor
Too little condensate in the air jet
Compressed-air pipeline leaking
Drain valve is open or missing
Discharge valve is leaking
Check valve insert is leaking or
defective
Check valve is damaged
Pressure relief reactivation:
Switch compressor off using the On/Off button. The appliance
will be relieved. Plug the appliance.
Switch the compressor using the On/Off button.
Service
Any technical questions? Complaint? Do you need spare
parts or operation manual?
Go to our website www.guede.com and the section Service will
help you quickly and without bureaucracy. Please, help us to help
you. In order to identify your device in case of complaint, please
indicate serial number, order number and year of manufacture. All
information is available on the product label. To have all
information always at hand, put them down.
Serial number:
Order number:
Year of manufacture:
Phone:
+49 (0) 79 04 / 700-360
Fax:
+49 (0) 79 04 / 700-51999
E-Mail:
support@ts.guede.com
Important information for the customer
Please be sure to know that returning the product in or after
the warranty period must be made in the original packaging.
Remedy
Release the pressure in the air jet so that the pressure
switch gets automatically switched on
Have the current supply checked by an authorised person
Have the pressure switch replaced by an authorised
person (Güde service centre)
Replace the carbons
Check the length and cross section of the electric cable
Clean or replace the suction filter
Check the pneumatic tool air consumption;
seek an authorised compressed air dealer
Localise the leaking, contact the Güde service centre
Drain the condensate
Check the compressed-air pipeline; remove the leaking
Close or insert the drain valve
Clean or replace the discharge valve
Clean or replace the check valve insert
Replace the check valve