8. Maintenance

WARNING:
- When carrying out maintenance or other work on the equipment: switch off the supply
voltage.
Operation is impaired by fouling of the bars.
Clean the bars with a hard (non-metal) brush.
Clean the bars with isopropyl alcohol when they are heavily fouled.
The other parts of the Conveyostat
It will usually be necessary to dismantle the Conveyostat
Attention:
- Do not damage the emitter points.
- Allow the equipment to dry properly before reusing it.

9. Faults

Problem
No high voltage
No ionisation
Table 1: Remedying faults of the Conveyostat

10. Repair

®
The Conveyostat
does not have any parts which can be repaired by the client. If the Con-
®
veyostat
is in need of repair, send it to Simco-Ion.
In this case, pack it properly and clearly state the reasons for return.

11. Disposal

Adhere to the applicable local environmental and other rules when disposing of the equipment.
®
Conveyostat
_UM_9752972310_NL_D_GB_F_V2_0
®
are maintenance-free.
Cause
High voltage power unit is
defective
Loose contact or cable
breakage
Fouling
®
Conveyostat
not earthed or
insufficiently earthed
®
.
®
for cleaning.
Remedy
Check the operation of the high voltage
power unit (please refer to the relevant
user's manual)
Check the connections and the cable
Clean the bars
Earth the Conveyostat
®
properly
GB
15