18
4
3
2
Figure 18: Dimensioning
1. 599 mm
2. 270 mm
3. 426 mm
4. 310 mm
Sauna heater installation Sense Commercial 6-20 (Fig. 19-22)
1.
Hang the heater on the screws see Fig. 19.
Figure 19: Hang the heater up.
2.
Lock the heater into place with the lock screw see Fig. 20.
Figure 20: Lock screw for bracket
3. Install the sensor on the wall see Fig 21. The thermistor wire
may also be passed through the wall. Seal any holes in the
wall behind the sensor, see Figure 22. The thermistor wire
may be extended outside the sauna using low voltage wire
(2-lead).
1
Figure 21: Installing the sensor
Figure 22: Wiring through the wall.
Unusual voltages/numbers of phases
Contact Tylö Customer Service before connecting to voltages or
numbers of phases that are not listed in the wiring diagram.
External ON/OFF switch (option)
The external ON/OFF switch can be positioned anywhere outside
the sauna, but not too far from the heater, to avoid voltage loss in
the cable. Voltage loss aff ects the LED indicator for heater status
(if built-in and connected to the switch).
For further information, see instructions supplied with the control
panel.
Door contact (option)
The door contact is necessary to be able to use the Elite panel's
calendar function, plus remote control the sauna via external
switch, mobile or PC apps.
See the instructions supplied with the control panel.