4
3
2
Figure 13: Dimensioning
1. 262 mm
2. 270 mm
3. 532 mm
4. 206 mm
8.
Fit herb bowl/air humidifi er (see Fig. 14).
Figure 14: Fitting the fragrance holder/air humidifi er
Sauna heater installation Sense Commercial 10-20 (Fig. 15-
18)
It is easiest to prepare for installation with the heater lying down.
To install the heater:
1.
Undo the screws and open the cover (see Figure 15).
Figure 15: Opening/closing the cover
WARNING! Always check that the heater is con-
nected to the correct main/phase voltage!
Connect the heater using standard wiring (Fk or EKK) approved
for fi xed installation.
Any single wires (Fk) must be protected in electrical conduits (VP)
to the heater.
2.
Connect the electrical cable (1) to the terminal (2) (see Figure
9) according to the wiring diagram (see the Connection/wiring
diagram section, page 19).
1
Figure 16: Electrical wiring
1. Electrical cable
2. Terminal for connection of electrical cable
3.
Connect the control panel, relay box (RB30) (if applicable)
and lighting (if applicable) according to the wiring diagram.
4.
Close the cover and tighten the screws (see Figure 15).
5.
Attaching the brackets to the heater
Figure 17: Attaching the brackets to the heater
6.
Position the bracket screws according to the specifi ed dimen-
sioning see Fig. 18.
Option 10-16-20 kW (See separate guide).