HSI150 DG
Safety instructions and information
Target group
The installation may only be carried out by technical experts.
Qualified and trained individuals carrying out installation must have
• knowledge of general safety and accident prevention regulations as amended,
• knowledge of how to use safety equipment,
• knowledge of how to use hand tools and electric tools,
• knowledge of the relevant standards and guidelines for laying pipes/cables and
for backfilling utility trenches as amended,
• knowledge of the regulations and installation guidelines of the supply company
as amended,
• knowledge of the waterproof concrete directive and building waterproofing
standards as amended.
General information and intended use
In line with their intended use, our products have been developed solely for instal-
lation in buildings made of state-of-the-art materials. Insofar as no express written
confirmation has been provided by us, we do not accept any liability for any other
purposes or purposes going beyond the above.
For warranty conditions, please see our current General Terms and Delivery Conditions.
We explicitly draw your attention to the fact that no warranty whatsoever applies
for any subsequent damage occurring as a result of failure to follow the installation
instructions or if our products are used incorrectly or combined with third-party products.
The HSI150 DG system cover is suitable for retrofitting and inserting cables to be
installed or already laid.
Safety
This section provides an overview of all the main safety aspects for optimum
protection of personnel and a safe installation process.
A failure to observe the instructions and safety information set out here may result
in significant hazards.
During installation it is imperative to observe the relevant professional association
rules, the VDE provisions, the relevant national safety and accident prevention
regulations and your company's guidelines (work and procedure instructions).
The fitter must wear the relevant protective clothing.
Only intact components may be installed.
The following instructions are to be observed prior to installa-
tion of the wall inserts:
WARNING!
Risk of injury in the event of improper installation!
Improper installation can result in significant bodily harm and property damage.
• The nationally applicable laying and filling regulations for pipes and cables are
to be observed at all times.
• Seal the underground and cable substructure well prior to laying pipes/cables
so that the latter cannot subside.
NOTICE!
No sealing due to incorrect installation!
Improper installation can result in damage.
• The incorrect laying of cables or ducts and improper filling of the cable
trench causes settlement, which can lead to damage and leaks.
• Do not open the blind cover of the wall insert until just before installing
the cable.
• Cables and pipes should not be supposed to mechanical load.
• Any cable entries that are not required may be used as pressure-tight back-
up entries if there is an undamaged Hauff quality seal on the closing cover.
• Do not knock the blind cover in with a hammer or sharp object!
• Open cable entries, which are to be used as back-up entries, or closing cover
which have been opened accidentally, should be fitted with new HSI150 DT/
DTS respectively HSI90 D blind covers!
• Do not reuse uninstalled or damaged closing covers!
• If a cable conduit must be at the outside is connected to a wall insert with a
plug-in socket, the socket side or the plug-in socket must sit on the outside
of the building or shaft when setting in concrete.
• When tapping in the safety cover (second sealing cover), the bayonet
mounting and the seal seat for the O-ring of the seal packing must not be
damaged.
• Before mounting a system cover in the wall insert, clean the interior of any
dirt and check the sealing surfaces for any damage.
• Before the process of installing the duct begins, the bottom of the trench
must be free from water and the bottom bedding layer must be created by
a professional in accordance with the installation guidelines provided by the
duct manufacturer.
• There must not be any continous longitidinal score marks on the cables in
the seal area (if necessary, move the cables slightly forwards or backwards
until there are no longitudinal score marks visible).
• No cleaning agents containing solvent may be used. We recommend using
the cable cleaner KRMTX.
• For details of other accessories and further information, see www.hauff-technik.
6
de and the technical data sheets as well as the safety data sheet.
EN
Personnel requirements
Qualifications
Risk of injury in case of inadequate qualification!
Improper handling can result in significant bodily harm and property damage.
• Installation may only be carried out by qualified and trained individuals who
have read and understood these instructions.
Skilled experts
Based on their specialist training, skills, experience and familiarity with the relevant
provisions, standards and regulations, skilled experts are able to carry out the
work assigned, independently identifying and avoiding potential hazards.
Transport, packaging, scope of delivery and storage
Safety instructions in connection with transport
NOTICE!
Damage in the event of improper transport!
Significant damage can occur in the event of improper transport.
• When unloading packaging items on delivery and in the course of in-house
transport, proceed with care and observe the symbols on the packaging.
Transport inspection
Inspect the delivery immediately on receipt for completeness and transport damage.
In the event of transport damage being visible from the outside, proceed as follows:
• Do not accept the delivery or only do so subject to reservations.
• Make a note of the extent of damage in the transport documentation or delivery
note provided by the transporter.
• Submit a claim for every defect as soon as it has been identified.
• Claims for damages can only be asserted within the applicable claim period.
Delivery scope
The HSI150 DG system cover is supplied with the following:
1 HSI150 DG press seal
1 HSI150 AR DG adapter ring
1 GM lubricant pen
1 knife
1 cleaning cloth
(3 sealing plugs suitable for HSI150 DG 3x24-54 or respectively
6 sealing plugs suitable for HSI150 DG 6x10-36)
Optional:
3 HSI150 PA 3x24-54 press plate covers suitable for HSI150 DG 3x24-54 or
1 HSI150 PA 6x10-36 press plate covers suitable for HSI150 DG 6x10-36
Storage
NOTE!
Damage due to improper storage!
Significant damage can occur in the event of improper storage.
• The wall entry is to be protected from damage, damp and soiling prior to
installation. Only intact components may be installed.
• The wall entry must be stored in such a way that it is not exposed to low tem-
peratures (<5 °C), high temperatures (>30 °C) or direct sunlight.
Disposal
If no return or disposal agreement has been concluded, recycle dismantled
components after they have been properly dismantled:
• Metal remains are to be scrapped according to existing environmental
regulations.
• Dispose of elastomers according to existing environmental regulations.
• Dispose of plastics according to existing environmental regulations.
• Dispose of packaging material according to existing environmental regulations.
Consignes de sécurité et informations
Public
Ce montage peut être effectué uniquement par des personnes compé-
tentes.
Les personnes qualifiées et formées pour le montage
• ont connaissance des règles de sécurité et de prévention actuellement en
vigueur,
• savent utiliser un équipement de sécurité,
• savent manier des outils manuels et électriques,
• ont connaissance des normes et directives actuellement en vigueur pour la pose
Art. Nr.: 5090032033
Rev.: 05/2020-04-28
WARNING!
respectively
FR