Logic
De nition
Address
ADDRESS
Con guration of
EXPI1 input on
input-output ex-
EXPI1
pansion board.
1-2
Con guration of
EXPI2 input
on input-output
EXPI2
expansion board.
1-3
Con guration of
EXPO2 output
on input-output
EXPO1
expansion board
4-5
Con guration of
EXPO2 output
on input-output
EXPO2
expansion board
6-7
Tra c light
TRAFFIC LIGHT
pre- ashing
PREFLASHING
TRAFFIC LIGHT
Steadily lit red
RED LAMP
light
ALWAYS ON
40 -
LEO B CBB DL2 3 230 L02-LEO B CBB DL2 3 120
INSTALLATION MANUAL
Cross out
Default
setting
used
Identi es board address from 0 to 119 in a local BFT network connection.
0
[ ___ ]
(see U-LINK OPTIONAL MODULES section)
0
Input con gured as Start E command.
1
Input con gured as Start I command.
2
Input con gured as Open command.
3
Input con gured as Close command.
4
Input con gured as Ped command.
5
Input con gured as Timer command.
6
Input con gured as Timer Pedestrian command.
7
Input con gured as Phot (photocell) safety.
8
Input con gured as Phot op safety (photocell active during opening only).
9
Input con gured as Phot cl safety (photocell active during closing only).
10
Input con gured as Bar safety (safety edge).
Input con gured as safety Bar OP, safety edge with inversion active only while opening, if while closing the
11
1
movement stops.
Input con gured as safety Bar CL, safety edge with inversion active only while closing, if while opening the
12
movement stops.
Input con gured as Phot test safety, tested photocell. Input 3 (EXPI2) on input/output expansion board is switched
13
automatically to safety device test input, EXPFAULT1.
Input con gured as Phot op test safety, tested photocell active only while opening. Input 3 (EXPI2) on input/
14
output expansion board is switched automatically to safety device test input, EXPFAULT1
Input con gured as Phot cl test safety, tested photocell active only while closing. Input 3 (EXPI2) on input/output
15
expansion board is switched automatically to safety device test input, EXPFAULT1
Input con gured as Bar safety, tested safety edge. Input 3 (EXPI2) on input/output expansion board is switched
16
automatically to safety device test input, EXPFAULT1.
Input con gured as safety Bar OP test, safety edge with inversion active only while opening, if while closing the
17
movement stops. Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device
test input, EXPFAULT1.
Input con gured as safety Bar CL test, safety edge with inversion active only while closing, if while opening the
18
movement stops. Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device
test input, EXPFAULT1.
0
Input con gured as Start E command.
1
Input con gured as Start I command.
2
Input con gured as Open command.
3
Input con gured as Close command.
4
Input con gured as Ped command.
5
Input con gured as Timer command.
6
Input con gured as Timer Pedestrian command.
0
7
Input con gured as Phot (photocell) safety.
8
Input con gured as Phot op safety (photocell active during opening only).
9
Input con gured as Phot cl safety (photocell active during closing only).
10
Input con gured as Bar safety (safety edge).
Input con gured as safety Bar OP, safety edge with inversion active only while opening, if while closing the
11
movement stops.
Input con gured as safety Bar CL, safety edge with inversion active only while closing, if while opening the
12
movement stops.
0
Output con gured as monostable Radio Channel.
1
Output con gured as SCA (gate open light).
2
Output con gured as Courtesy Light command.
11
3
Output con gured as Zone Light command.
4
Output con gured as Stair Light.
5
Output con gured as Alarm.
6
Output con gured as Flashing light.
7
Output con gured as Latch.
8
Output con gured as Magnetic lock.
9
Output con gured as Maintenance.
10
Output con gured as Flashing Light and Maintenance.
11
11
Output con gured as Tra c Light control with TLB board.
12
Output con gured as Antitampering
13
Output con gured as Gate Status
14
Output con gured as Bistable Radio Channel
Output con gured as timed Radio Channel
15
0
Pre- ashing switched o .
0
1
Red lights ash, for 3 seconds, at start of operation.
0
Red lights o when gate closed.
0
1
Red lights on when gate closed.
F02-LEO B CBB DL2 3 120 F02 PHOT USA16