Télécharger Imprimer la page

BFT LEO B CBB DL2 3 230 L02 Instructions D'utilisation page 34

Masquer les pouces Voir aussi pour LEO B CBB DL2 3 230 L02:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 42
2) GENERAL INFORMATION
TheLEO B CBB DL2 3 230 L02 - LEO B CBB DL2 3 120 F02- LEO B CBB DL2 3
120 F02 PHOT USA16 control panel comes with standard factory settings. Any
change must be made using the programmer with built-in display or universal
handheld programmer. The Control unit completely supports the EELINK protocol.
Its main features are:
-
Control of 1 single-phase motor
-
Electronic torque control
-
Obstacle detection
-
Separate inputs for safety devices
-
Con gurable command inputs
-
Built-in radio receiver rolling code with transmitter cloning.
The board has a terminal strip of the removable kind to make maintenance
or replacement easier. It comes with a series of prewired jumpers to make the
installer's job on site easier.
The jumpers concern terminals: 70-71, 70-72, 70-74, 76-77. If the above-
mentioned terminals are being used, remove the relevant jumpers.
LEO B CBB DL2
3 230 L02
Power supply
220-230V~
50Hz/60Hz
Obstacle
detection with
Present
encoder
Output for
terminals 26-27:
AUX3
N.O. contact
con gurable
(24V~/0,5A)
TESTING
The LEO B CBB DL2 3 230 L02 - LEO B CBB DL2 3 120 F02- LEO B CBB DL2 3
120 F02 PHOT USA16 panel controls (checks) the start relays and safety devices
(photocells) before performing each opening and closing cycle.
If there is a malfunction, make sure that the connected devices are working
properly and check the wiring.
WIRING AND TERMINAL BOARD CONFIGURATION
Terminal
De nition
L
N
NEUTRAL
GND
EARTH
10
START + CAP
11
12
START + CAP
AUX 0 - POWERED CONTACT
220 230V~
20
(LEO B CBB DL2 3 230 L02)
POWERED CONTACT 120V~
(LEO B CBB DL2 3 120 F02)
(LEO B CBB DL2 3 120 F02 PHOT USA16)
21
26
AUX 3 - FREE CONTACT (N.O.)
LEO B CBB DL2 3 230 L02
LEO B CBB DL2 3 120 F02
27
OUTPUT CONFIGURED AS UL
26
LEO B CBB DL2 3 120 F02 PHOT
27
USA16
41
+ REF SWE
42
43
JP32
50
51
52
24 Vsafe+
60
Common
61
62
63
Common
64
65
34 -
LEO B CBB DL2 3 230 L02-LEO B CBB DL2 3 120
INSTALLATION MANUAL
LEO B CBB DL2 3
LEO B CBB DL2 3 120
120 F02
F02 PHOT USA16
120V~ ±10%
120V~ ±10%
50Hz/60Hz
50Hz/60Hz
Present
Present
Only for sw versions
Only for sw versions
7.08
8.08
Output for audible
AUX3 con gurable
signal
Single-phase power supply
LINE
(LEO B CBB DL2 3 230 L02).
Single-phase power supply 120V~ ±10%, 50-60Hz, with earth cable
(LEO B CBB DL2 3 120 F02/ LEO B CBB DL2 3 120 F02 PHOT USA16).
Motor connection.
START + CAP Motor Start and capacitor
COM
COM Motor Common
START + CAP Motor Start and capacitor
AUX 0 con gurable output - Default setting FLASHING LIGHT.
MONOSTABLE RADIO CHANNEL/ SCA GATE OPEN LIGHT/ COURTESY LIGHT command/ ZONE LIGHT command/ STAIR LIGHT/
GATE OPEN ALARM/ FLASHING LIGHT/ SOLENOID LATCH/ MAGNETIC LOCK/ MAINTENANCE/ FLASHING LIGHT AND MAINTE-
NANCE / ANTITAMPERING / GATE STATUS / BISTABLE RADIO CHANNEL / TIMED RADIO CHANNEL.
Refer to "AUX output con guration" table.
AUX 3 con gurable output - Default setting MONOSTABLE RADIO CHANNEL Output.
MONOSTABLE RADIO CHANNEL/ SCA GATE OPEN LIGHT/ COURTESY LIGHT command/ ZONE LIGHT command/ STAIR
LIGHT/ GATE OPEN ALARM/ FLASHING LIGHT/ SOLENOID LATCH/ MAGNETIC LOCK/ MAINTENANCE/ FLASHING LIGHT AND
MAINTENANCE / GATE STATUS / BISTABLE RADIO CHANNEL / TIMED RADIO CHANNEL.
Refer to "AUX output con guration" table.
ALARM
Activation: 2 consecutive obstacle detections uninterrupted by an end stop
Deactivation: after 300s or after removal of the "STOP" input
Limit switch common
SWC
Closing limit switch SWC (N.C.). (Do not connect or jump if there is the magnetic limit switch)
SWO
- Opening limit switch SWO (N.C.). (NDo not connect or jump if there is the magnetic limit switch)
Magnetic limit switch connection
24V-
Accessories power supply output.
24V+
Tested safety device power supply output (photocell transmitter and safety edge transmitter).
Output active only during operating cycle.
IC 1 and IC 2 inputs common
Con gurable command input 1 (N.O.) - Default START E.
IC 1
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input con guration" table.
Con gurable command input 2 (N.O.) - Default PED.
IC 2
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input con guration" table.
IC 3 and IC 4 inputs common
Con gurable command input 3 (N.O.) - Default OPEN.
IC 3
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input con guration" table.
Con gurable command input 4 (N.O.) - Default CLOSE.
IC 4
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input con guration" table.
F02-LEO B CBB DL2 3 120 F02 PHOT USA16
3) TECHNICAL SPECIFICATIONS
Power supply
Low voltage/mains insulation
Operating temperature range
Thermal overload protection
Dielectric rigidity
Maximum motor power
Accessories power supply
AUX 0
AUX 3/ Output for audible signal
Dimensions
Fuses
N° of combinations
Max.n° of transmitters that can be memorized 63
Usable transmitter versions:
All ROLLING CODE transmitters compatible with
4) TUBE ARRANGEMENT Fi g. A
5) TERMINAL BOARD WIRING Fig. B
WARNINGS - When performing wiring and installation, refer to the standards in
force and, whatever the case, apply good practice principles.
Wires carrying di erent voltages must be kept physically separate from each other,
or they must be suitably insulated with at least 1mm of additional insulation.
Wires must be secured with additional fastening near the terminals, using devices
such as cable clamps.
All connecting cables must be kept far enough away from the dissipater.
Description
220-230V
50/60Hz
~
, with earth cable
220-230V~ 50Hz/60Hz
(LEO B CBB DL2 3 230 L02)
120V~ ±10% 50Hz/60Hz
(LEO B CBB DL2 3 120 F02/ LEO B CBB DL2
3 120 F02 PHOT USA16)
> 2MOhm 500V
-20 / +55°C
Built into motor
mains/LV 3750V~ for 1 minute
750W
24V~ (demand max. 1A)
24V~safe
220-230V~N.O. (40W max)
(LEO B CBB DL2 3 230 L02)
powered contact
120V~N.O. (40W max)
(LEO B CBB DL2 3 120 F02/ LEO B CBB DL2
3 120 F02 PHOT USA16)
powered contact
NO contact (24V~/max.0,5A)
146x170x60mm